High-resolution mapping of scar-related atrial arrhythmias using smaller electrodes with closer interelectrode spacing.
نویسندگان
چکیده
BACKGROUND The resolution of mapping is influenced by electrode size and interelectrode spacing. Smaller electrodes with closer interelectrode spacing may improve mapping resolution, particularly in scar. The aims of this study were to establish normal electrogram criteria in the atria for both 3.5-mm electrode tip linear catheters (Thermocool) and 1-mm multielectrode-mapping catheters (Pentaray) and to compare their mapping resolution in scar-related atrial arrhythmias. METHODS AND RESULTS Normal voltage amplitude cutoffs for both catheters were validated in 10 patients with structurally normal atria. In 20 additional patients with scar-related atrial arrhythmias, similar sequential mapping with both catheters was performed. Normal bipolar voltage amplitude was similar between 3.5- and 1-mm electrode catheters with a fifth percentile of 0.48 and 0.52 mV, respectively (P=0.65). In patients with scar-related atrial arrhythmias, the total area of bipolar voltage <0.5 mV measured using 1-mm electrode catheters was smaller than that measured using 3.5-mm catheter (14.7 versus 20.4 cm2; P=0.02). The mean bipolar voltage amplitude in this area of low voltage was significantly higher with 1-mm electrode catheters (0.28 and 0.17 mV; P=0.01). Importantly, 54.4% of all low voltage data points recorded with 1-mm electrode catheter had distinct electrograms that allowed annotation of local activation time compared with only 21.4% with 3.5-mm electrode tip catheters (P=0.01). Overdrive pacing with capture of the tachycardia from within the area of low voltage was more frequent with 1-mm electrode catheters (66.7 versus 33.4; P=0.01). CONCLUSIONS Mapping with small closely spaced electrode catheters can improve mapping resolution within areas of low voltage.
منابع مشابه
Electrogram fractionation: the relationship between spatiotemporal variation of tissue excitation and electrode spatial resolution.
BACKGROUND Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). METHODS AND RESULTS Using a computer model, we generated tissue activation patterns with increasi...
متن کاملThe Relationship Between Spatiotemporal Variation of Tissue Excitation and Electrode Spatial Resolution
Background—Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). Methods and Results—Using a computer model, we generated tissue activation patterns with increasing...
متن کاملRight atrial tachycardias related to regions of low-voltage myocardium in patients without prior cardiac surgery: catheter ablation and follow-up results.
AIMS There are only few descriptions of patients without prior cardiac surgery in whom a large low-voltage zone (LVZ) or scar is the electrophysiological substrate for various atrial tachycardias. We describe the electrophysiological and electroanatomic characteristics of unusual macroreentrant atrial tachycardias (MRATs) in seven patients with spontaneous right atrial (RA) scarring and present...
متن کاملTheoretical considerations for mapping activation in human cardiac fibrillation.
Defining mechanisms for cardiac fibrillation is challenging because, in contrast to other arrhythmias, fibrillation exhibits complex non-repeatability in spatiotemporal activation but paradoxically exhibits conserved spatial gradients in rate, dominant frequency, and electrical propagation. Unlike animal models, in which fibrillation can be mapped at high spatial and temporal resolution using o...
متن کاملCorrelation of Scar in Cardiac MRI and High‐Resolution Contact Mapping of Left Ventricle in a Chronic Infarct Model
BACKGROUND Endocardial mapping for scars and abnormal electrograms forms the most essential component of ventricular tachycardia ablation. The utility of ultra-high resolution mapping of ventricular scar was assessed using a multielectrode contact mapping system in a chronic canine infarct model. METHODS Chronic infarcts were created in five anesthetized dogs by ligating the left anterior des...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2015