Assessment of pericardial constraint in dogs.

نویسندگان

  • O A Smiseth
  • M A Frais
  • I Kingma
  • E R Smith
  • J V Tyberg
چکیده

To determine the better method of measuring pericardial constraint, pericardial pressure was recorded by a liquid-filled open-ended catheter and a liquid-containing flat balloon in six open-chest anesthetized dogs. Left ventricular pressure was measured by a micromanometer-tipped catheter and left ventricular anteroposterior diameter was measured by sonomicrometry. Left ventricular end-diastolic pressure was raised to 20 +/- 1.7 (mean +/- SD) mm Hg by intravenous saline. Left ventricular diastolic pressure-diameter loops were constructed (1) with incremental amounts of saline (0 to 50 ml) in the resealed pericardium, (2) with several small holes in the pericardium, and (3) with the pericardium widely open. Measured pericardial pressures were compared with what was assumed to be the correct pericardial pressure, i.e., the calculated difference between left ventricular diastolic pressure (at a given left ventricular diameter) before and after opening the pericardium. Pressure recorded by the flat balloon was similar to the calculated pericardial pressure at all pericardial liquid volumes. Pressure recorded by the open-ended catheter, however, was significantly lower (p less than .05) than the calculated pressure unless there was at least 30 ml of liquid in the pericardium. After several holes had been made in the pericardium it still exerted a constraining effect, as shown by a marked rightward or downward shift of the left ventricular diastolic pressure-diameter relationships after completely opening the pericardium. After holes were made in the pericardium pressure recorded by the flat balloon was still similar to the calculated pericardial pressure. However, pressure recorded by the open-ended catheter was significantly (p less than .02) lower than the calculated pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pericardial effusion in a dog concurrent with carcinoma of unknown primary origin

Background: Pericardial effusion (PE) due to secondary metastasis has rarely been reported in dogs. Case description: This case describes clinical signs and further diagnostics regarding metastatic carcinoma of unknown primary origin (CUP) in refractory PE of a dog. Findings/treatment and outcome: A nine-year-old, castrated mal...

متن کامل

Nonuniformity of pericardial surface pressure in dogs.

Previously, we have shown that pericardial constraint cannot be measured by true (hydrostatic) pressure except when an excess of pericardial fluid is present and that a device such as a balloon (which reflects radial contact stress as well as hydrostatic pressure) must be used. Since radial contact stress is the major component of the constraint exerted by the pericardium when little pericardia...

متن کامل

Assessment of pericardial constraint: the relation between right ventricular filling pressure and pericardial pressure measured after pericardiocentesis.

Experimental studies have shown that right ventricular filling pressure (that is, intracavitary diastolic pressure) approximates pericardial surface pressure but, in many patients after removal of pericardial effusion, right ventricular filling pressure has been found to markedly exceed pericardial pressure recorded by an open catheter. The aim of this study was to determine whether this appare...

متن کامل

The use of the diaphragmatico-hepatic (DH) views of the abdominal and thoracic focused assessment with sonography for triage (AFAST/TFAST) examinations for the detection of pericardial effusion in 24 dogs (2011-2012).

OBJECTIVE To evaluate the clinical usefulness of the diaphragmatico-hepatic (DH) view of the abdominal and thoracic focused assessment with sonography for triage (AFAST/TFAST) in detecting pericardial effusion (PE) in dogs. DESIGN Retrospective case series from 2011 to 2012. SETTING Private practice emergency and critical care hospital. ANIMALS Twenty-four dogs with PE diagnosed by FAST. ...

متن کامل

Use of Multidetector Computed Tomography in the Assessment of Dogs with Pericardial Effusion

BACKGROUND Contrast-enhanced multidetector computed tomography (MDCT) allows high spatial and temporal resolution imaging of cardiac, thoracic, and abdominal structures. Accurate determination of the cause of pericardial effusion (PE) is essential to providing appropriate treatment and prognosis. Echocardiography and pericardial fluid analysis may not differentiate between causes of PE and cann...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 71 1  شماره 

صفحات  -

تاریخ انتشار 1985