Intensity-Modulated Radiation Therapy for Rectal Carcinoma Can Reduce Treatment Breaks and Emergency Department Visits
نویسندگان
چکیده
Purpose. To compare the acute toxicities of IMRT to 3D-conformal radiation therapy (3DCRT) in the treatment of rectal cancer. Methods and Materials. Eighty-six patients with rectal cancer preoperatively treated with IMRT (n = 30) and 3DCRT (n = 56) were retrospectively reviewed. Rates of acute toxicity between IMRT and 3DCRT were compared for anorexia, dehydration, diarrhea, nausea, vomiting, weight loss, radiation dermatitis, fatigue, pain, urinary frequency, and blood counts. Fisher's exact test and chi-square analysis were applied to detect statistical differences in incidences of toxicity between these two groups of patients. Results. There were fewer hospitalizations and emergency department visits in the group treated with IMRT compared with 3DCRT (P = 0.005) and no treatment breaks with IMRT compared to 20% with 3DCRT (P = 0.0002). Patients treated with IMRT had a significant reduction in grade ≥3 toxicities versus grade ≤2 toxicities (P = 0.016) when compared to 3DCRT. The incidence of grade ≥3 diarrhea was 9% among 3DCRT patients compared to 3% among IMRT patients (P = 0.31). Conclusions. IMRT for rectal cancer can reduce treatment breaks, emergency department visits, hospitalizations, and all grade ≥3 toxicities compared to 3DCRT. Further evaluation and followup is warranted to determine late toxicities and long-term results of IMRT.
منابع مشابه
Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma
Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...
متن کاملA method for standardizing intensity modulated radiation therapy planning optimization for nasopharyngeal carcinoma
Background: To investigate a method for standardizing intensity modulated radiation therapy (IMRT) optimization for nasopharyngeal carcinoma (NPC), in order to reduce the influence of subjective factors. Materials and Methods: This study is based on example IMRT plans for NPC, which were randomly divided into data acquisition and data verification groups. Organs at risk (OARs) were analyzed for...
متن کاملClustering of nasopharyngeal carcinoma intensity modulated radiation therapy plans based on k-means algorithm and geometrical features
Background: The design of intensity modulated radiation therapy (IMRT) plans is difficult and time-consuming. The retrieval of similar IMRT plans from the IMRT plan dataset can effectively improve the quality and efficiency of IMRT plans and automate the design of IMRT planning. However, the large IMRT plans datasets will bring inefficient retrieval result. Materials and Methods: An intensity-m...
متن کاملInfluence of Compensator Thickness and Field Size on Buildup factor of a Brass Compensator for Intensity- Modulated Radiation Therapy
Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...
متن کاملComprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film
Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012