Clinical accuracy evaluation of femoral canal preparation using the ROBODOC system.

نویسندگان

  • Shunsaku Nishihara
  • Nobuhiko Sugano
  • Takashi Nishii
  • Hisashi Tanaka
  • Nobuo Nakamura
  • Hideki Yoshikawa
  • Takahiro Ochi
چکیده

The purpose of this study was to evaluate the clinical accuracy of femoral canal preparation using postoperative reconstructed computed tomography (CT) images of 75 consecutive total hip arthroplasties performed with a two-pin-based ROBODOC system. Intraoperatively, the robot milled the femoral canal according to the preoperative planning performed with preoperative CT data and the ROBODOC workstation. Postoperative CT data was obtained 1 month postoperatively. Anteroposterior and lateral synthetic radiographs and axial images were reconstructed from CT data on the workstation. The mean difference between the preoperative planning and the postoperative CT images was less than 5% in canal fill, less than 1 mm in gap, and less than 1 degrees in the mediolateral and anteroposterior alignment. Clinical femoral canal preparation using the ROBODOC system results in a high degree of accuracy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of the ROBODOC system in preventing intraoperative pulmonary embolism.

Intraoperative pulmonary embolism occurs not only during cemented but also during cementless total hip arthroplasty (THA). We determined whether the ROBODOC femoral milling system can reduce intraoperative pulmonary embolism, by using of transesophageal echocardiography and hemodynamic monitoring. We did a prospective clinical trial with 71 patients (75 hips) who were divided into 2 groups: gro...

متن کامل

Cement Removal from the Femur Using the ROBODOC System in Revision Total Hip Arthroplasty

Introduction. The perforation and fracture of the femur during the removal of bone cement in revision total hip arthroplasty (THA) are serious complications. The ROBODOC system has been designed to selectively remove bone cement from the femoral canal, but results have not been reported yet. The purpose of our study was to evaluate the clinical and radiographic results of revision THA using the...

متن کامل

Primary and revision total hip replacement using the Robodoc system.

The ROBODOC system was designed to address potential human errors in performing cementless total hip replacement. The system consists of a preoperative planning computer workstation (called ORTHODOC) and a five-axis robotic arm with a high speed milling device as an end effector. The combined experience of the United States Food and Drug Administration multicenter trial and the German postmarke...

متن کامل

Comparative study on canal preparation by three rotary sys-tems using CT scan (An in vitro study)

Comparative study on canal preparation by three rotary sys-tems using CT scan (An in vitro study) Dr. M.H. Zarrabi* - Dr. A. Talati** - Dr. S. Moradi** - Dr. L. Shakeri*** * - Associate Professor and Chief of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Assistant Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Scien...

متن کامل

Evaluation of Canal Transportation and Centering Ability of Safesider and K-Flexofile: Using Cone-beam Computed Tomography

Abstract Background and aim: Maintaining the original geometry of canal is an important parameter in successful root canal treatment. The aim of this original study was evaluation of apical root canal transportation and centering ability of SafeSider and K-Flexofile using cone beam computed tomography. Materials and Methods: Mesiobuccal root canals of maxillary first molars, with 20-40° curvatu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 2004