Targeted Pressure on Abductor Hallucis and Flexor Hallucis Brevis Muscles to Manage Moderate to Severe Primary Restless Legs Syndrome.
نویسندگان
چکیده
CONTEXT Restless legs syndrome (RLS) treatments have included medications with many adverse effects and limited utility. A noninvasive device would potentially have extensive use where RLS medications may not be appropriate, such as in pregnant or breastfeeding women, people with mild RLS, people who operate machinery or drive occupationally, people with severely impaired renal function, or people who are taking medications contraindicated with RLS medications. OBJECTIVE To assess the efficacy and safety of a device that produces targeted pressure on the abductor hallucis and the flexor hallucis brevis muscles to reduce the symptoms of moderate to severe RLS, and to compare the current findings with findings from studies of ropinirole use in patients with primary RLS. METHODS This 8-week single-arm, open-label, clinical trial with a repeated measures design was conducted between April 2009 and August 2012 in 2 offices in Erie, Pennsylvania. Adults with moderate to severe primary RLS were recruited for the study. Mean (SD) follow-up was 15.6 (6) months. Patients wore RLS devices (1 on each foot) for set periods intermittently throughout the course of the study. The primary end point was mean change in the International Restless Legs Syndrome Study Group (IRLSSG) Rating Scale from baseline to day 56, and the secondary measure was the Clinical Global Impression scale. A meta-analysis was used to compare the RLS device findings with the findings of 3 historic studies of ropinirole vs placebo. The demographics, disease severity, inclusion and exclusion criteria, and assessment tools were similar among the 4 studies. RESULTS Thirty patients (22 women, 8 men; mean age, 51.5 years [range, 30-75 years]) participated in the study. Change in mean (SD) IRLSSG score was significantly greater for the RLS device (17.22 [6.16]; P<.001) compared with the ropinirole vs placebo findings (12 [0.86] vs 8.9 [0.86], respectively; P<.05). Sleep loss significantly decreased from 119.5 (61.6) minutes to 22.1 (31.1) minutes per night (P<.001). Global Improvement Scale scores indicated significantly greater improvement with the RLS device compared with ropinirole (27 of 30 [90%] vs 293 of 464 [63%], respectively; P<.05). Mild, transient adverse effects of the device (eg, pain, paresthesia) were reported, but these effects were relieved by loosening the straps. The RLS device demonstrated none of the adverse effects associated with current dopamine agonist therapy, such as augmentation, tolerance, rebound, somnolence, and nausea. CONCLUSION Producing targeted pressure on the abductor hallucis and flexor hallucis brevis muscles with an external RLS device reduced the symptoms of moderate to severe primary RLS without the adverse effects of medication therapy. (ClinicalTrials.gov number NCT02386423.) J Am Osteopath Assoc.
منابع مشابه
Reliability of ultrasound to measure morphology of the toe flexor muscles
BACKGROUND Measuring the strength of individual foot muscles is very challenging; however, measuring muscle morphology has been shown to be associated with strength. A reliable method of assessing foot muscle atrophy and hypertrophy would therefore be beneficial to researchers and clinicians. Thus, the aim of this study was to evaluate the test-retest intra-observer reliability of ultrasound to...
متن کاملUltrasound evaluation of foot muscles and plantar fascia in pes planus.
BACKGROUND Multiple intrinsic and extrinsic soft tissue structures that apply forces and support the medial longitudinal arch have been implicated in pes planus. These structures have common functions but their interaction in pes planus is not fully understood. The aim of this study was to compare the cross-sectional area (CSA) and thickness of the intrinsic and extrinsic foot muscles and plant...
متن کاملUltrasound evaluation of intrinsic plantar muscles and fascia in hallux valgus
A cross-sectional area (CSA) and thickness reduction of the abductor hallucis (AbH) is shown in subjects with hallux valgus (HV). To date, other soft-tissue structures have not been researched in relation with HV. The aim of this study was to compare the CSA and thickness of the intrinsic plantar muscles and fascia (PF) between feet with and without HV. Therefore, a cross-sectional and case-con...
متن کاملRecruitment of the plantar intrinsic foot muscles with increasing postural demand.
BACKGROUND The aim of this study was to determine the difference in activation patterns of the plantar intrinsic foot muscles during two quiet standing tasks with increasing postural difficulty. We hypothesised that activation of these muscles would increase with increasing postural demand and be correlated with postural sway. METHODS Intra-muscular electromyographic (EMG) activity was record...
متن کاملDoes the weakening of intrinsic foot muscles cause the decrease of medial longitudinal arch height?
[Purpose] There are no reliable evidences that the weakening of intrinsic foot muscles causes the decrease of the medial longitudinal arch (MLA) height. The purpose of this study was to confirm whether the fatigue of intrinsic foot muscles decrease the MLA height during standing and gait using 3D motion analysis system. [Subjects and Methods] Twenty healthy male subjects participated in this st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the American Osteopathic Association
دوره 116 7 شماره
صفحات -
تاریخ انتشار 2016