An improved leaping detector for flow analysis applied to iron speciation in drugs

نویسندگان

  • Sérgio R. B. Santos
  • Mário C. U. Araújo
  • Ricardo S. Honorato
  • Elias A. G. Zagatto
  • José F. C. Lima
  • Rui A. S. Lapa
چکیده

A low inner volume (ca. 64 ml) probe was built up in an injector-commutator in order to behave as a photometric leaping detector in flow analysis. It comprises a bicolour light-emitting diode (BLED), as a source of pulsed radiation in the red and green visible region, and two phototransistors as transducers. Sample injection, detector relocation, analytical signal recording, data treatment and definition of the spectral working range were computer-controlled. The feasibility of the system was initially demonstrated in the flow-injection speciation of iron, and the overall standard deviation of results was estimated as +/- 1.6 and +/- 1.4% for 1.6-4.0 mg l(-1) Fe(II) or total iron after eightfold processing of synthetic samples. The system was further applied to drug analysis: the mean deviations of results for typical samples were estimated as +/- 5.2 and +/- 3.3%, and the relative standard deviation as +/- 1.6 and +/- 1.3% for Fe(II) and total iron, respectively. Results were compared with those obtained by a conventional spectrophotometric procedure and no statistic differences at the 95% confidence level were found. In relation to an earlier system with multi-site detection, the proposed system is more stable, presenting low drift with a relative standard deviation of 0.026% and 0.039% for measurements (n=120 during 4 h of observation) with green and red emission. It is also faster with a sampling rate of 133 h(-1) and carryover problems are not found. The possibility of compensating the Schlieren noise by dual-wavelength spectrophotometry is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Combined Heat and Power Economic Dispatch using Improved Shuffled Frog Leaping Algorithm

Recently, Combined Heat and Power (CHP) systems have been utilized increasingly in power systems. With the addition penetration of CHP-based co-generation of electricity and heat, the determination of economic dispatch of power and heat becomes a more complex and challenging issue. The optimal operation of CHP-based systems is inherently a nonlinear and non-convex optimization problem with a lo...

متن کامل

Covariance Analysis of a vector tracking GPS receiver based on MMSE multiuser Detection

In high dynamic conditions, using vector tracking loops instead of scalar tracking loops in GPS receivers is proved as an efficient method to compensate the performance. The Minimum Mean Squared Error detector as a multiuser detector is applied in the vector tracking loop for more reliability and efficiency. The Kalman filter does the two tasks of tracking and extracting the navigation data aft...

متن کامل

Use of the Improved Frog-Leaping Algorithm in Data Clustering

Clustering is one of the known techniques in the field of data mining where data with similar properties is within the set of categories. K-means algorithm is one the simplest clustering algorithms which have disadvantages sensitive to initial values of the clusters and converging to the local optimum. In recent years, several algorithms are provided based on evolutionary algorithms for cluster...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Automated Methods and Management in Chemistry

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2000