In vitro validation of flow measurement with phase contrast MRI at 3 tesla using stereoscopic particle image velocimetry and stereoscopic particle image velocimetry-based computational fluid dynamics.
نویسندگان
چکیده
PURPOSE To validate conventional phase-contrast MRI (PC-MRI) measurements of steady and pulsatile flows through stenotic phantoms with various degrees of narrowing at Reynolds numbers mimicking flows in the human iliac artery using stereoscopic particle image velocimetry (SPIV) as gold standard. MATERIALS AND METHODS A series of detailed experiments are reported for validation of MR measurements of steady and pulsatile flows with SPIV and CFD on three different stenotic models with 50%, 74%, and 87% area occlusions at three sites: two diameters proximal to the stenosis, at the throat, and two diameters distal to the stenosis. RESULTS Agreement between conventional spin-warp PC-MRI with Cartesian read-out and SPIV was demonstrated for both steady and pulsatile flows with mean Reynolds numbers of 130, 160, and 190 at the inlet by evaluating the linear regression between the two methods. The analysis revealed a correlation coefficient of > 0.99 and > 0.96 for steady and pulsatile flows, respectively. Additionally, it was found that the most accurate measures of flow by the sequence were at the throat of the stenosis (error < 5% for both steady and pulsatile mean flows). The flow rate error distal to the stenosis was primarily found to be a function of narrowing severity including dependence on proper Venc selection. CONCLUSION SPIV and CFD provide excellent approaches to in vitro validation of new or existing PC-MRI flow measurement techniques.
منابع مشابه
Comparisons of Experimental and Simulated Velocity Fields in Membrane Module Spacers
Spacers are used in spiral wound and plate and frame membrane modules to create flow channels between adjacent membrane layers and mix fluid within the flow channel. Flow through the spacer has a significant beneficial impact on mixing and resulting mass transfer rates but is accompanied by an undesirable increase in pressure drop. Computational Fluid Dynamics (CFD) is a common tool used to eva...
متن کاملFluid Dynamics Investigation of a GDI Fuel Spray by Particle Image Velocimetry
In this work, result of experimental investigation on interaction of fuel spray generated by a swirled type injector, with air motion in a prototype cylinder are presented. Experiments were carried out by planar imaging and particle image velocimetry (PIV) techniques in order to provide information about the spray structure evolution and instantaneous velocity distribution of air motion and ...
متن کاملAccuracy of flow measurement with phase contrast MRI in a stenotic phantom: where should flow be measured?
Methods Herein, a series of detailed experiments are reported for validation of MR measurements of steady and pulsatile flows with stereoscopic particle image velocimetry (SPIV) on three different stenotic models with 50%, 74%, and 87% area occlusions. Mean inlet Reynolds number was 190 for both steady and pulsatile cases, mimicking the flow of the human common iliac artery. Axial PC-MRI images...
متن کاملHeat Transfer Enhancement of a Flat Plate Boundary Layer Distributed by a Square Cylinder: Particle Image Velocimetry and Temperature-Sensitive Paint Measurements and Proper Orthogonal Decomposition Analysis
The current empirical study was conducted to investigate the wall neighborhood impact on the two-dimensional flow structure and heat transfer enhancement behind a square cylinder. The low- velocity open-circle wind tunnel was used to carry out the study tests considering the cylinder diameter (D)-based Reynolds number (ReD) of 5130. The selected items to compare were different gap he...
متن کاملVelocity measurement of near-wall flow over inclined and curved boundaries by extended interfacial particle image velocimetry
Particle image velocimetry (PIV) measurements near a curved boundary usually require efforts to deal with low tracer density, high shear gradient andwall reflection. To resolve these difficulties, we presented a near-wall measurement technique named interfacial PIV (IPIV) that could return a tangential velocity component and a tangential component of wall gradient [Nguyen TD, Wells J, Nguyen C....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 39 6 شماره
صفحات -