Intra-Examiner and Inter-Examiner Reproducibility of Paraspinal Thermography
نویسندگان
چکیده
OBJECTIVE The objective of this study was to evaluate the intra-examiner and inter-examiner reproducibility of paraspinal thermography using an infrared scanner. MATERIALS AND METHODS The thermal functions of a commercially available infrared scanner (Insight Subluxation Station®) were evaluated for clinical reliability. Two practicing clinicians conducted the measures on 100 subjects. Intra class correlation coefficients (ICCs) and concordance correlation coefficients (CCCs) were calculated from the collected data. RESULTS Mean bilateral paraspinal skin temperature was 89.78° F and ranged from 88.77° F to 91.43° F. Intra class correlation coefficients (ICCs) for agreement and consistency ranged from 0.959 to 0.976. Concordance correlation coefficients (CCCs) ranged from 0.783 to 0.859 with tight confidence intervals indicating robust estimates of these quantities. CONCLUSION This study revealed excellent intra-examiner and inter-examiner reproducibility of paraspinal thermography using a commercially available unit.
منابع مشابه
Reproducibility of Frankfort Horizontal Plane on 3D Multi-Planar Reconstructed MR Images
OBJECTIVE The purpose of this study was to determine the accuracy and reliability of Frankfort horizontal plane identification using displays of multi-planar reconstructed MRI images, and propose it as a sufficiently stable and standardized reference plane for craniofacial structures. MATERIALS AND METHODS MRI images of 43 subjects were obtained from the longitudinal population based cohort s...
متن کاملEvaluating intra- and inter-examiner reproducibility in histometric measurement: one-wall intrabony periodontal defects in beagle dogs
PURPOSE Accurate and exact measurement is an important factor for generating meaningful results in any properly designed study. If all the participating examiners are able to yield similar results, it will be possible to evaluate the objective results of the study more easily and quickly. The purpose of this study was to evaluate the intra- and inter-examiner reproducibility of histometric meas...
متن کاملAssessment of Intra- and Inter-examiner Reproducibility of Probing Depth Measurements with a Manual Periodontal Probe
BACKGROUND AND AIMS The main purpose of this study was to assess intra- and inter-examiner reproducibility of probing depth measurements with a manual periodontal probe. MATERIALS AND METHODS In this study, 32 dental students in Tabriz Faculty of Dentistry with normal periodontium were evaluated. Each tooth of the upper right quadrants, except the third molars, was examined. Probing depths we...
متن کاملIntra- and inter-examiner reproducibility of manual probing depth.
The periodontal probe remains the best clinical diagnostic tool for the collection of information regarding the health status and the attachment level of periodontal tissues. The aim of this study was to evaluate intra- and inter-examiner reproducibility of probing depth (PD) measurements made with a manual probe. With the approval of an Ethics Committee, 20 individuals without periodontal dise...
متن کاملBrief communication: dentists’ reproducibility in scoring the plaque index using a fluorescent colouring agent
Statement of the problem: Fluorescein is a plaque detection agent, which fluoresces yellow-green when excited with blue light (dental light curing lamp). Little is known about the reproducibility of scoring with the Silness-Löe plaque index (1964) when using this agent. Purpose of the study: To evaluate the level of agreement of the plaque index measurements using a fluorescent colouring agent ...
متن کامل