A Japanese prospective multi-institutional feasibility study on accelerated partial breast irradiation using interstitial brachytherapy: treatment planning and quality assurance

نویسندگان

  • Yuki Otani
  • Takayuki Nose
  • Takushi Dokiya
  • Toshiaki Saeki
  • Yu Kumazaki
  • Shuuji Asahi
  • Iwao Tsukiyama
  • Ichirou Fukuda
  • Hiroshi Sekine
  • Naoto Shikama
  • Takao Takahashi
  • Ken Yoshida
  • Tadayuki Kotsuma
  • Norikazu Masuda
  • Eisaku Yoden
  • Kazutaka Nakashima
  • Taisei Matsumura
  • Shino Nakagawa
  • Seiji Tachiiri
  • Yoshio Moriguchi
  • Jun Itami
  • Masahiko Oguchi
چکیده

BACKGROUND In Japan, breast-conserving surgery with closed cavity has generally been performed for breast cancer patients, and accelerated partial breast irradiation (APBI) is considered difficult because Asian females generally have smaller breast sizes than Western females. Therefore, common identification of target and treatment plan method in APBI is required. A prospective multicenter study was conducted in Japan to determine institutional compliance with APBI using high-dose-rate interstitial brachytherapy (ISBT) designed for Japanese female patients. METHODS For this study, 46 patients were recruited at eight institutions from January 2009 to December 2011. The reproducibility of the ISBT-APBI plan was evaluated using three criteria: (1) minimum clinical target volume dose with a clip dose ≥ 6 Gy/fraction, (2) irradiated volume constraint of 40-150 cm(3), and (3) uniformity of dose distribution, expressed as the dose non-uniformity ratio (DNR, V150/V100) < 0.35. The ISBT-APBI plan for each patient was considered reproducible when all three criteria were met. When the number of non-reproducible patients was ≤ 4 at study completion, APBI at this institution was considered statistically reproducible. RESULTS Half of the patients (52 %) had a small bra size (A/B cup). The mean values of the dose-constrained parameters were as follows: Vref, 117 cm(3) (range, 40-282), DNR, 0.30 (range, 0.22-0.51), and clip dose, 784 cGy (range, 469-3146). A total of 43/46 treatment plans were judged to be compliant and ISBT-APBI was concluded to be reproducible. CONCLUSIONS This study showed that multi-institutional ISBT-APBI treatment plan was reproducible for small breast patient with closed cavity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...

متن کامل

Multi-catheter interstitial brachytherapy for partial breast irradiation: an audit of implant quality based on dosimetric evaluation comparing intra-operative versus post-operative placement

PURPOSE The use of multicatheter interstitial brachytherapy (MIB) for accelerated partial breast irradiation (APBI) in early breast cancer (EBC) patients outside the trial setting has increased. Hence, there is a need to critically evaluate implant quality. Moreover, there is a scarcity of reports using an open cavity technique. We report the dosimetric indices of open and closed cavity MIB tec...

متن کامل

Projected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis

Accelerated partial breast irradiation has caused higher than expected rates of poor cosmesis. At our institution, a novel breast stereotactic radiotherapy device has demonstrated dosimetric distributions similar to those in brachytherapy. This study analyzed comparative dose distributions achieved with the device and intensity-modulated radiation therapy accelerated partial breast irradiation....

متن کامل

Multi-catheter interstitial accelerated partial breast irradiation – tips and tricks for a good insertion

Adjuvant radiotherapy is recommended post breast conserving surgery. Accelerated Partial Breast Irradiation (APBI) offers a more attractive shorter course of treatment over 5 days compared to standard conventional external beam radiotherapy, which is often protracted. Multi-catheter interstitial APBI offers excellent dosimetric coverage. This article describes two insertion techniques for multi...

متن کامل

Accelerated partial breast irradiation: potential roles following breast-conserving surgery.

BACKGROUND Multiple randomized trials comparing mastectomy to lumpectomy and whole breast irradiation (WBI) have shown equivalent survival outcomes in early-stage breast cancer. WBI requires a treatment course of several weeks, which has resulted in limited access to breast-conserving therapy in certain populations. A shorter accelerated course of partial breast irradiation (APBI) has been inve...