Pulmonary artery trauma due to balloon dilation: recognition, avoidance and management.

نویسندگان

  • C M Baker
  • F X McGowan
  • J F Keane
  • J E Lock
چکیده

OBJECTIVES We reviewed the management and outcome of patients experiencing pulmonary artery (PA) trauma during balloon dilation (BD). BACKGROUND Balloon dilation of the PA is important in the management of peripheral pulmonary stenosis. Successful BD requires a controlled tear of the PA; excessive tearing can produce complications ranging from pseudoaneurysms to rupture and death. The incidence and optimum management for such complications are unreported. METHODS All records of patients who underwent branch PA dilation between June 1984 and October 1997 were reviewed; those with a significant complication were analyzed. RESULTS Of 1,286 catheterizations in 782 patients, PA trauma (excluding isolated pulmonary edema and PA aneurysms) was identified in 29 catheterizations in 26 patients. Tears occurred distal to the area of stenosis in most cases (62%). Intensive medical management, with and without catheter directed therapy, was employed. The damaged PA was successfully coil embolized in five patients, four of whom survived; temporary balloon occlusion did not prevent death in two patients. There were six deaths from pulmonary hemorrhage. A case control analysis demonstrated that PA trauma was significantly associated with pulmonary hypertension. CONCLUSIONS Pulmonary artery trauma associated with BD occurs mostly distal to the site of narrowing, is associated with underlying pulmonary hypertension and is frequently (5/12 or 42%) fatal in those with unconfined tears. Intensive management strategies as well as attention to distal balloon position may reduce incidence and mortality. Coil occlusion of the damaged PA appears to be a valuable strategy to prevent fatal hemorrhage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Silent Pulmonary Artery Dissection in a patient with old Pulmonary Balloon Valvuloplasty

Percutaneous pulmonary balloon valvuloplasty (PBV) remains the treatment of choice for pulmonary stenosis (PS). This procedure is effective, safe and gives excellent results. Pulmonary artery (PA) dissection is a rare complication of PBV. This report is a case of an asymptomatic 17-year-old male with a history of PBV due to severe PS dating back to fifteen years ago. During recent echocardiogra...

متن کامل

Balloon dilation angioplasty of peripheral pulmonary stenosis associated with Williams syndrome.

BACKGROUND Experience of balloon dilation of peripheral pulmonary stenosis (PPS) in Williams syndrome (WS) is limited. METHODS AND RESULTS Catheterizations in all patients with WS undergoing therapy for PPS from 1984 to 1999 were reviewed. Criteria for successful dilation included an increase >50% in predilation diameter and a decrease >20% in ratio of right ventricular (RV) to aortic (Ao) sy...

متن کامل

Tetralogy of Fallot with diminutive pulmonary arteries: preoperative pulmonary valve dilation and transcatheter rehabilitation of pulmonary arteries.

OBJECTIVES This study sought to determine the results of a novel transcatheter management approach in tetralogy of Fallot with diminutive pulmonary arteries. BACKGROUND Tetralogy of Fallot with diminutive pulmonary arteries and severe pulmonary stenosis is rare and resembles tetralogy of Fallot with pulmonary atresia: There is a high incidence of aortopulmonary collateral channels, arborizati...

متن کامل

Dilatable pulmonary artery banding in infants with low birth weight or complex congenital heart disease allows avoidance or postponement of subsequent surgery.

OBJECTIVE This study evaluated the efficiency and feasibility of dilatable bands in selected patients. METHODS Two types of dilatable handmade bands were retrospectively evaluated and divided into two groups: main pulmonary artery bands and bilateral branch pulmonary artery bands (hybrid stage I palliation). Stepwise balloon angioplasty (BA) was performed, increasing the diameter either to co...

متن کامل

CLINICAL INVESTIGATION Morphologic changes in the pulmonary arteries after percutaneous balloon angioplasty for pulmonary arterial stenosis

The pathologic appearance of pulmonary arteries subjected to balloon dilation was studied in four subjects with stenosis of pulmonary arteries. Nine vessels were dilated. Successful dilation in seven vessels was accompanied by intimal disruption and tearing of the media. In one vessel, at the site of a previous surgical procedure, dilation could not be accomplished. Histologically, this vessel ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2000