Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

نویسندگان

  • Hiromichi Ito
  • Shonosuke Matsushita
  • Kazuyuki Hyodo
  • Yukio Sato
  • Yuzuru Sakakibara
چکیده

Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

Quantification of Lung Perfusion Blood Volume by Dual-Energy CT in Patients With and Without Chronic Obstructive Pulmonary Disease

The introduction of a dual-source CT system in the same gantry resolved many of the technical issues that previously limited the application of dual-energy CT pulmonary angiography. Dual-energy CT pulmonary angiography does not expose patients to any significant additional radiation beyond that of standard CT pulmonary angiography [1, 2]. Post-processing software is then used to subtract 80-kV ...

متن کامل

Assessing pulmonary perfusion in emphysema: automated quantification of perfused blood volume in dual-energy CTPA.

OBJECTIVES The objective of this study was to determine whether automated quantification of lung perfused blood volume (PBV) in dual-energy computed tomographic pulmonary angiography (DE-CTPA) can be used to assess the severity and regional distribution of pulmonary hypoperfusion in emphysema. MATERIALS AND METHODS We retrospectively analyzed 40 consecutive patients (mean age, 67 [13] years) ...

متن کامل

Imaging of the pulmonary circulation in the closed-chest rat using synchrotron radiation microangiography.

Structural changes of the pulmonary circulation during the pathogenesis of pulmonary arterial hypertension remain to be fully elucidated. Although angiography has been used for visualizing the pulmonary circulation, conventional angiography systems have considerable limitations for visualizing small microvessels (diameters < 200 microm), particularly within a closed-chest animal model. In this ...

متن کامل

Correlation of myocardial Tc 99m-MIBI perfusion SPECT with coronary angiography in Namazi Hospital/Shiraz/Iran [Persian]

Coronary heart disease (CAD) is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of CAD and is suggested by many investigators in recent years. In this study, 64 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2013