Opt- Design of Experiments for Sensor Calibration
نویسنده
چکیده
In this paper we present a framework for the design of experiments for sensor calibration. The theoretical ideas, which are based on the mathematical theory of optimal design of experiments, are demonstrated using a new software program, I-OPT, which was developed by Crary, Snow, and Hoo.' This program has been used to find I-optimal designs for both a silicon capacitive absolute-pressure sensor and a silicon piezoresistive pressure sensor.
منابع مشابه
A New Approach to Self-Localization for Mobile Robots Using Sensor Data Fusion
This paper proposes a new approach for calibration of dead reckoning process. Using the well-known UMBmark (University of Michigan Benchmark) is not sufficient for a desirable calibration of dead reckoning. Besides, existing calibration methods usually require explicit measurement of actual motion of the robot. Some recent methods use the smart encoder trailer or long range finder sensors such ...
متن کاملOptimal Design of Experiment for Medical Sensors Calibration
This paper presents a framework for the optimal design of experiments for medical sensors calibration. A new software program, G-optimal, is developed to demonstrate the optimal design of experiment. This program has been used to find G-optimal design for amperometric enzyme glucose sensor, silicon capacitive absolute pressure sensors and electrochemical oxygen and carbon dioxide partial pressu...
متن کاملAn Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams
This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...
متن کاملDesign and Evaluation and Synthesis a Starch-Capped Silver NanoParticles Sensor and Determination trace Sulfacetamide Drug in the Presence Sodium borohydride in Blood and Urine Samples with Kinetic Spectrophotometric Method
A new Kinetic Spectrophotometic method for the Determination of trace amount Sulfacetamide Drug into real samples has been described based with silver nanoparticles starch-capped sensor, by sodium borohydride. The reaction is followed spectrophotometrically by measuring the decrease in the absorbance at 347.5 nm. 1.0×10-2 molL-1 silver nanoparticles starch-capped sensor, 2.0×10-3 mol L-1 sodium...
متن کاملDisposable single-use electrochemical sensor: A novel hollow fiber based tool for environmental monitoring of cadmium
The objective of this study is to design a simple, fast, sensitive and single-use electrode with the simultaneous capability of preconcentration and measuring, for application in a three-electrode voltammetry system to identify and measure the heavy metal cadmium. The design process of this sensor consists of several stages. The polyurethane foam and multi walled carbon nanotubes nanoparticles ...
متن کامل