Impact of PET acquisition durations on image quality and lesion detectability in whole-body 68Ga-PSMA PET-MRI
نویسندگان
چکیده
BACKGROUND While 68Ga-PSMA PET-MRI might be superior to PET-CT with regard to soft tissue assessment in prostate cancer evaluation, it is also known to potentially introduce additional PET image artefacts. Therefore, the impact of PET acquisition duration and attenuation data on artefact occurrence, lesion detectability, and quantification was investigated. To this end, whole-body PET list mode data from 12 patients with prostate cancer were acquired 1 h after injection of 2 MBq/kg [68Ga]HBED-CC-PSMA on a hybrid PET-MRI system. List mode data were further transformed into data sets representing 300, 180, 90, and 30 s acquisition duration per bed position. Standard attenuation and scatter corrections were performed based on MRI-derived attenuation maps, complemented by emission-based attenuation data in areas not covered by MRI. A total of 288 image data sets were reconstructed with varying acquisition durations for emission and attenuation data with and without scatter and prompt gamma correction, and further analysed regarding image quality and diagnostic performance. RESULTS Decreased PET acquisition durations resulted in a significantly increased incidence of halo artefacts around kidneys and bladder, decreased lesion detectability and lower SUV as well as markedly lower arm attenuation values: Halo artefacts were present in 5 out of 12 cases at 300-s duration, in 6 at 180 s, in 10 at 90 s, and in 11 cases at 30 s. Using attenuation data of the 300 s scans restored artefact occurrence to the original 300-s level. Prompt gamma correction only led to small improvements in terms of artefact occurrence and size. Of the 141 detected lesions in the 300-s images one lesion was not detected at 180 s, 28 at 90 s, and 64 at 30 s. Using the 300-s attenuation map decreased non-detectability of lesions to zero at 180 s, 9 at 90 s, and 52 at 30 s. Attenuation maps at 90 and 30 s demonstrated markedly lower mean arm attenuation values (0.002 cm-1) than those at 300 s (0.084 cm-1), and 180 s (0.062 cm-1). CONCLUSIONS Short acquisition durations of less than 3 minutes per bed position result in unacceptable image artefacts and decreased diagnostic performance in current whole-body 68Ga-PSMA PET-MRI and should be avoided. Increased image noise and imperfections in generated attenuation maps were identified as a paramount cause for image degradation.
منابع مشابه
Optimization of Acquisition time of 68Ga-PSMA-Ligand PET/MRI in Patients with Local and Metastatic Prostate Cancer
OBJECTIVE The aim of this optimization study was to minimize the acquisition time of 68Ga-HBED-CC-PSMA positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with local and metastatic prostate cancer (PCa) to obtain a sufficient image quality and quantification accuracy without any appreciable loss. METHODS Twenty patients with PCa were administered intravenously with t...
متن کاملIntegrated 68Ga-HBED-CC-PSMA-PET/MRI in patients with suspected recurrent prostate cancer.
AIM Evaluate the diagnostic accuracy of 68Ga-labeled HBED-CC-PSMA-PET/MRI for detection of recurrent PCa in comparison to PET/CT. METHODS 48 patients with suspected recurrent PCa underwent PET/CT after injection of the 68Ga-HBED-CC-PSMA ligand followed by integrated PET/MRI. Image analysis was performed by nuclear medicine physicians and radiologists with respect to the detection of lymph nod...
متن کاملManual production and quality control of 68Ga-PSMA-11 radiopharmaceutical for PET-CT imaging of prostate cancer: optimization and 60 production series experience
Background: 68Ga-PSMA-11, a novel PET radiopharmaceutical, is currently used for imaging of almost all prostate cancers. However, automatic radiolabeling procedures have been recommended. In this research, according to the chemical nature of the PSMA-11, manual, optimized and safe production of this radiopharmaceutical has been investigated and a standard method has been presented to achieve a ...
متن کاملMeningioma: A false positive finding of metastasis from prostate adenocarcinoma using 68Ga-PSMA PET/CT scan
A 73-year-old man with history of prostatic adenocarcinoma radical prostatectomy underwent 99mTc-MDP whole-body bone scan and subsequent 68Ga-labeled prostate-specific membrane antigen (PSMA) ligand PET/CT for restaging due to a gradual rise of prostate-specific antigen levels. Whole-body bone scan showed two focal zones of slightly increased uptake in the right fronto-par...
متن کاملOptimal MRI sequences for 68Ga-PSMA-11 PET/MRI in evaluation of biochemically recurrent prostate cancer
BACKGROUND PET/MRI can be used for the detection of disease in biochemical recurrence (BCR) patients imaged with 68Ga-PSMA-11 PET. This study was designed to determine the optimal MRI sequences to localize positive findings on 68Ga-PSMA-11 PET of patients with BCR after definitive therapy. Fifty-five consecutive prostate cancer patients with BCR imaged with 68Ga-PSMA-11 3.0T PET/MRI were retros...
متن کامل