ElectrophoreticSeparationof High-DensityLipoproteinCholesterol Evaluated and Compared with the Modified LipidResearch Clinic Procedure
نویسندگان
چکیده
We evaluated a new agarose-gel-electrophoretic procedure (Corning) (I) for separatingandquantitating of highdensity lipoprotein cholesterol (HDLC), comparing it with the modified Lipid Research Clinics (LRC) procedure (heparin 183 kilounits/L, MnCI2 92 mmol/L) (U). Method I was insensitive to an HDLC concentration of 50 mg/L, but gave a linear dose-response curve between 130 and 1200 mg/L. Method II is sensitive to 50 mg/L and linear from 50-1200 mg/L. The within-plate CV for the Corning method varied from 26.2% for an HDLC of 168 mg/L to 6.8% for 580 mg/L. Within-day between-plate CV for the Corning method ranged from 22.1% at 155 mg/Lto 8.0% at 651 mg/L, compared to3.0 and 0.8% for the modified LRC procedure. Between-day CV for method I was 20, 12.6, 4.3, and 3.5% for HDLC concentrations of 175, 435, 542, and 678 mg/L, respectively; for method II it was 14, 5, 3.5, and 2.6%, respectively. Analysis of HDLC in 100 patients by both procedures showed mean HDLC values to be significantly lower(+ SD, 27.8 :1: 1.7 mg/L; p < 0.00 1) by method I. In 46 patients with HDLC <450 mg/L, this difference was accentuated ( J SD = 40.5 J 2.6 mg/L) and clinically significant. Electrophoretic methods offer a promising further alternative method for HDLC separation and quantitation, but the negative bias, present limited sensitivity, and lack of precision at <450 mg/L indicate that they are not yet optimal for routine clinical use for patients with values <450 mg/L.
منابع مشابه
استخراج DNA از ریشه مو با روش نمکی بهینه یافته
The reliability and performance of the molecular diagnostic assays such as polymerase chain reaction (PCR), enzyme digestion and other applications are influence by quantity and quality of the extracted DNA strongly. Furthermore, to choose suitable and optimal tissue for genomic experiments nevertheless consider quantity and quality of the extracted DNA, we need to consider the comfort of sampl...
متن کاملThe Relationship between Modified Biophysical Profile, Standard Biophysical Profile, and Neonatal Outcomes of High-risk Pregnancies
Introduction: High-risk pregnancies can result in many complications for the fetus. In these pregnancies, different tests such as non-stress test (NST), biophysical profile (BPP), oxytocin contraction stress test (OCT), and Doppler sonography can be used to evaluate fetal health. As standard BBP requires more time and expertise, in this study, we evaluated the relationship between standard BPP,...
متن کاملImage Retrieval Using Dynamic Weighting of Compressed High Level Features Framework with LER Matrix
In this article, a fabulous method for database retrieval is proposed. The multi-resolution modified wavelet transform for each of image is computed and the standard deviation and average are utilized as the textural features. Then, the proposed modified bit-based color histogram and edge detectors were utilized to define the high level features. A feedback-based dynamic weighting of shap...
متن کاملEffects of modified atmosphere packaging on microbiological load and physico-chemical properties of barramundi (Lates calcarifer Bloch) fillets at 8°C
Different modified atmosphere conditions with various CO2 concentrations on microbial load (psychrophile, mesophile aerobic and anaerobic bacteria) and physico-chemical properties of barramundi (Lates calcarifer Bloch) fillets stored at 8°C were compared to determine the best packaging conditions. The gas conditions evaluated were 100% CO2 (M1), 75% CO2/25% N2 (M2), 50% CO2/50% N2 (M3), 25% CO...
متن کاملThe Effect of the Modified Cloze Procedure on the Writing Proficien-cy of Iranian Intermediate EFL Learners
The present study was conducted to investigate the effect of modified cloze procedure on writing proficiency of Iranian intermediate EFL learners. To fulfill the purpose of the study, 110 participants studying at Semnan University majoring in English literature were tested on CELT proficiency test. 65 participants who were found to be homogenous were selected and assigned randomly to two groups...
متن کامل