Corneal Biomechanical Findings in Contact Lens Induced Corneal Warpage

نویسندگان

  • Fateme Alipour
  • Mojgan Letafatnejad
  • Amir Hooshang Beheshtnejad
  • Seyed-Farzad Mohammadi
  • Seyed Reza Ghaffary
  • Narges Hassanpoor
  • Mehdi Yaseri
چکیده

Purpose. To evaluate the difference in biomechanical properties between contact lens induced corneal warpage and normal and keratoconic eyes. Method. Prospective observational case control study, where 94 eyes of 47 warpage suspicious and 46 eyes of 23 keratoconic patients were included. Warpage suspected cases were followed until a definite diagnosis was made (warpage, normal, or keratoconus). Results. 44 eyes of 22 patients had contact lens related corneal warpage. 46 eyes of 23 people were diagnosed as nonwarpage normal eyes. 46 eyes of 23 known keratoconus patients were included for comparison. The mean age of the participants was 23.8 ± 3.8 years, and 66.2% of the subjects were female. The demographic and refractive data were not different between warpage and normal groups but were different in the keratoconus group. The biomechanical properties (corneal hysteresis or CH and corneal resistance factor or CRF) were different with the highest value in the warpage group followed by normal and keratoconus groups. CRF was 10.08 ± 1.75, 9.23 ± 1.22, and 7.38 ± 2.14 and CH was 10.21 ± 1.57, 9.59 ± 1.21, and 8.69 ± 2.34 in the warpage, normal, and keratoconus groups, respectively. Conclusion. Corneal biomechanics may be different in people who develop contact lens induced warpage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differentiating Keratoconus and Corneal Warpage by Analyzing Focal Change Patterns in Corneal Topography, Pachymetry, and Epithelial Thickness Maps

PURPOSE To differentiate between keratoconus and contact lens-related corneal warpage by combining focal change patterns in anterior corneal topography, pachymetry, and epithelial thickness maps. METHODS Pachymetry and epithelial thickness maps of normal, keratoconus, and warpage, and forme fruste keratoconus (FFK) eyes were obtained from a Fourier-domain optical coherence tomography (OCT). E...

متن کامل

Corneal Biomechanical Changes Following Toric Soft Contact Lens Wear

PURPOSE To determine the effect of using toric soft contact lenses on corneal biomechanical properties. METHODS We enrolled 33 healthy patients with mean age of 23.18 ± 4.06 and minimal cylinder power of 1 D (-1.98 ± 0.808 SD) and negative history of contact lens use; keratoconic patients were excluded from the study. Toric soft contact lenses (BIOFINITY, Comfilcon A, Coopervision, Southampto...

متن کامل

Changes in corneal biomechanics and applanation tonometry with induced corneal swelling.

PURPOSE To investigate the changes in Goldmann applanation tonometry (GAT) and Ocular Response Analyzer (ORA) measurements with corneal edema induced by contact lenses. METHODS Twenty-five healthy, normal subjects (age, 23 ± 2 years) had central corneal radius (CCR), ORA, GAT, and central corneal thickness (CCT) measurements performed in both eyes before a thick, soft hydrogel contact lens wa...

متن کامل

Airbag induced corneal ectasia.

PURPOSE To report a case of airbag induced corneal ectasia. METHODS Case report. RESULTS A patient 3 years post-LASIK developed bilateral corneal ectasia worse in the right eye following airbag deployment in a road traffic accident. At last follow up, best corrected vision was 20/40 with -4.00/-4.00 x 25 in the right eye and 20/25 with -1.25/-0.50 x 135 in the left eye. CONCLUSIONS This i...

متن کامل

امکان استفاده از آنزیم EcoR1 در طبقه بندی سویه های اکانتامبای ایزوله شده از التهاب قرنیه

Acanthamoeba keratitis is increasingly being diagnosed among people who wear thrapeutic and cosmetic contact lenses. The chain of events is thought to begin with contamination of the contact lens storage cases with Acanthamoeba from household or mains water supplies. If bacteria contamination is also present then these amoebas can multiply by ingesting the bacteria as a food source. If the cont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016