This paper introduces a simple, inexpensive, and robust quantitative proteomic method for quantifying N-linked glycoproteins based on isotope-coded carbamidomethylation (iCCM) incorporated into an online microbore hollow fiber enzyme reactor and nanoflow liquid chromatography-tandem mass spectrometry (mHFER-nLC-MS/MS). The iCCM quantitation uses carbamidomethylation (CM; a routine protection of thiol groups before proteolysis) of the Cys residue of proteins with iodoacetamide (IAA) or its isotope (IAA-(13)C2,D2: 4 Da difference). CM-/iCCM-labeled proteome samples are mixed for proteolysis; then, online enrichment of N-glycopeptides using lectin affinity is carried out in an mHFER before nLC-MS/MS for quantification using multiple reaction monitoring (MRM). Initial evaluation of the iCCM method varying the mixing ratio of CM-/iCCM-labeled bovine serum albumin (BSA) standards yielded successful quantification of 18 peptides with less than 2% variation in the calculated ratio of light/heavy-labeled peptides. The iCCM quantitation with mHFER-nLC-MS/MS was evaluated with three standard glycoproteins (α-1-acid glycoproteins, fetuin and transferrin) and then applied to serum glycoproteins from liver cancer patients and controls, resulting in successful quantification of 73 N-glycopeptides (from 49 N-glycoproteins), among which 19 N-glycopeptides from 14 N-glycoproteins showed more than a 2.5-fold aberrant change in liver cancer patients' sera compared with the pooled control. Although iCCM quantitation with mHFER-nLC-MS/MS applies only to glycopeptides with Cys residue, the method can offer several advantages over other labeling methods when applied to targeted glycoproteins: The iCCM method does not require an additional labeling reaction under special conditions nor complicated procedures to purify labeled products using additional columns. Isotope labeling at the protein level can minimize potential uncertainty originating from unequal efficiencies in protein digestion in separate vials and retrieval of each labeled peptide when labeling takes place at the peptide level. In addition, the labeling reagents for the iCCM method are readily obtained at a reasonable cost, which can make protein quantification easily accessible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lectin-based enrichment method for glycoproteomics using hollow fiber flow field-flow fractionation: application to Streptococcus pyogenes.

This paper presents a new application of hollow fiber flow field-flow fractionation (HF5) as a preparative method to preconcentrate high mannose type N-linked glycoproteins from Streptococcus pyogenes by means of the mannose-specific binding affinity between concanavalian A (ConA) and N-linked glycosylated proteins. Prior to fractionation of N-linked glycoproteins from bacterial lysates, it was...

متن کامل

Online Miniaturized Asymmetrical Flow Field-Flow Fractionation and Inductively Coupled Plasma Mass Spectrometry for Metalloprotein Analysis of Plasma from Patients with Lung Cancer.

Metalloproteins (metal-binding proteins) refer to proteins containing metal ion cofactors. The importance of these proteins has increased owing to their involvement in many biological processes. Here, we introduce an analytical platform based on online coupling of miniaturized asymmetrical flow field-flow fractionation (mAF4) and inductively coupled plasma mass spectrometry (ICPMS) for size sep...

متن کامل

A New Enhanced, Rapid and Precise Sample Preparation Protocol for Label-free Protein Quantification

Tandem mass spectrometry (MS/MS) in combination with nanoflow liquid chromatography (LC) has become the analytical technique of choice for global relative quantification assays of complex protein samples [1]. Methodologies have been developed to enable the comparison of protein expression levels across multiple samples, which may be broadly classified as either label-free, or those incorporatin...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 86 15  شماره 

صفحات  -

تاریخ انتشار 2014