New kinetic method for creatinine measurement now automated in the Cobas Fara centrifugal analyzer.

نویسندگان

  • C Cocco
  • M Schinella
  • U Lippi
چکیده

A new kinetic method to determine creatimne in serum by using an alkaline 3,5-dinitrobenzoate solution was recently reported (1). Interference from pseudo-creatinine chromogens, bilirubin, or triacylglycerols was negligible. The results obtained with this kinetic spectrophotometric assay, performed with an Eppendorf ACP 5040 analyzer, agreed well with the procedure of Jaff#{233}, as modified by Helger et al. (2). The procedure, however, requires that the changes in absorbance be measured in very short time intervals after the start of the reaction. We have automated this procedure (1) for determination of serum creatimne for use with a Cobas Fara centrifugal analyzer (F. Hoffmann-La Roche, Basle, Switzerland). The reagents consist of (a) 0.3 mol/L solution of 3,5-dimtrobenzoic acid (Carlo Erba, Milano, Italia; cat. no 405274) in 0.3 molfL NaOH and (b) 0.5 mol/L NaOH. The instrument settings were as follows:

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An enzymatic method for oxalate automated with the Cobas Fara centrifugal analyzer.

Measurement of oxalate in urine has been automated for use with the Cobas Fara centrifugal analyzer. No sample pretreatment other than (a critical) pH adjustment is required. Between-run CVs were less than 4%. Results were linearly related to oxalate concentration to 1000 mumol/L. Ascorbic acid ingestion, up to 5 g of ascorbate daily, caused no demonstrable interference with the assay. This pra...

متن کامل

Automated determination of angiotensin-converting enzyme in serum.

This is an adaptation of the Fujirebio "ACEcolor" kit for automated measurement of angiotensin-converting enzyme (EC 3.4.15.1) in serum with the Cobas Fara centrifugal analyzer. The linear range extends to an activity of 110 U/L. Results obtained by the present method and by the manual method were identical, and correlated closely (r = 0.983) with those by Cushman's modified method. The referen...

متن کامل

Automated analysis for free and short-chain acylcarnitine in plasma with a centrifugal analyzer.

We describe a fully automated, spectrophotometric assay of free and total carnitine in plasma ultrafiltrates. The method, suitable for routine application in most hospital laboratories, incorporates the hydrolysis of acylcarnitines to free carnitine within the program of a Cobas Fara II centrifugal analyzer. The hydrolysis is monitored and calibrated with standard solutions containing octanoylc...

متن کامل

Phenylalanine determined in plasma with use of phenylalanine dehydrogenase and a centrifugal analyzer.

Quantitative determination of plasma phenylalanine (Phe) is essential for the diagnosis of phenylketonuria (PKU) and the control of dietary therapy of PKU patients. We have adapted a spectrophotometric method (Clin Chim Acta 1991;201:95-8) based on phenylalanine dehydrogenase (EC 1.4.1.-) for rapid and accurate determinations of Phe with the Cobas Fara II centrifugal analyzer. The method is bas...

متن کامل

Fluorimetric methods for the measurement of intermediate metabolites (lactate, pyruvate, alanine, β-hydroxybutyrate, glycerol) using a COBAS FARA centrifugal analyser

Intermediate products of the metabolism of glucose, fat and amino-acid are important in the evaluation of such metabolic disorders as diabetes mellitus, liver disease and metabolic acidosis. In the present study, methods for the measurement of intermediate metabolites (lactate, pyruvate, alanine, beta-hydroxybutyrate and glycerol) have been adapted to a fast centrifugal analyzer: the COBAS FARA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 12  شماره 

صفحات  -

تاریخ انتشار 1988