Noninvasive measurement of myocardial activity concentrations and perfusion defect sizes in rats with a new small-animal positron emission tomograph.

نویسندگان

  • Takashi Kudo
  • Kazuki Fukuchi
  • Alexander J Annala
  • Arion F Chatziioannou
  • Vivekanand Allada
  • Magnus Dahlbom
  • Yuan-Chuan Tai
  • Masayuki Inubushi
  • Sung-Cheng Huang
  • Simon R Cherry
  • Michael E Phelps
  • Heinrich R Schelbert
چکیده

BACKGROUND We explored the feasibility of measuring regional tracer activity concentrations and flow defects in myocardium of rats with a high spatial resolution small-animal PET system (microPET). METHODS AND RESULTS Myocardial images were obtained after intravenous (18)F-fluorodeoxyglucose (18FDG) in 11 normal rats (group 1) and assembled into polar maps. Regional 18F activity concentrations were measured in 9 regions of interest and compared with tissue activity concentrations measured by well counting. In another 9 rats (group 2), myocardial perfusion images were acquired with 13N-ammonia at baseline and during coronary occlusion. On the polar maps recorded during coronary occlusion, the size of perfusion defects was measured as the myocardium with <50% of maximum activity and expressed as percent total myocardium and was correlated with the area at risk defined by postmortem staining. The diagnostic quality of 18FDG and 13N-ammonia microPET images was good to excellent; the images were easily assembled into polar maps. In group 1, regional (18)F concentrations by microPET and postmortem were correlated linearly (r=0.99; P<0.01 for average and r=0.97; P<0.01 for regional concentrations). In group 2, perfusion defect sizes by microPET and postmortem were correlated linearly (P<0.01; r=0.93). CONCLUSIONS The findings indicate the feasibility of noninvasive studies of the myocardium in rats with a dedicated small-animal PET-imaging device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

F-Labeled Positron-Emission Tomography Perfusion Tracer for the Assessment of Myocardial Infarct Size in Rats

Background—The goal of this study was to evaluate a new F-labeled positron-emission tomography (PET) perfusion tracer, F BMS747158-02, for the assessment of myocardial infarct (MI) size. Methods and Results—Wistar rats were studied 24 hours after ligation of the left coronary artery either permanently (n 15) or transiently (n 16) for 30 minutes. Seven nonoperated rats were studied as controls. ...

متن کامل

Evaluation of a novel (18)F-labeled positron-emission tomography perfusion tracer for the assessment of myocardial infarct size in rats.

BACKGROUND The goal of this study was to evaluate a new (18)F-labeled positron-emission tomography (PET) perfusion tracer, (18)F BMS747158-02, for the assessment of myocardial infarct (MI) size. METHODS AND RESULTS Wistar rats were studied 24 hours after ligation of the left coronary artery either permanently (n=15) or transiently (n=16) for 30 minutes. Seven nonoperated rats were studied as ...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease

Objectives This study aimed to determine the diagnostic accuracy of the 3 most commonly used noninvasive myocardial perfusion imaging modalities, single-photon emission computed tomography (SPECT), cardiac magnetic resonance (CMR), and positron emission tomography (PET) perfusion imaging for the diagnosis of obstructive coronary artery disease (CAD). Additionally, the effect of test and study c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 106 1  شماره 

صفحات  -

تاریخ انتشار 2002