Two-degree-of-freedom powered prosthetic wrist.

نویسندگان

  • Peter J Kyberd
  • Edward D Lemaire
  • Erik Scheme
  • Catherine MacPhail
  • Louis Goudreau
  • Greg Bush
  • Marcus Brookeshaw
چکیده

Prosthetic wrists need to be compact. By minimizing space requirements, a wrist unit can be made for people with long residual limbs. This prosthetic wrist uses two motors arranged across the arm within the envelope of the hand. The drive is transmitted by a differential so that it produces wrist flexion and extension, pronation and supination, or a combination of both. As a case study, it was controlled by a single-prosthesis user with pattern recognition of the myoelectric signals from the forearm. The result is a compact, two-degree-of-freedom prosthetic wrist that has the potential to improve the functionality of any prosthetic hand by creating a hand orientation that more closely matches grasp requirements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bowden Cable Based Powered Ball and Socket Wrist Actuator

A 2-Degrees of freedom powered prosthetic wrist actuator has been proposed that can provide the Abduction/Adduction & Flexion/Extension movements of the human wrist. The basic structure of the actuator is a Ball and Socket joint and the force is transmitted from the DC geared servo motors to the joint through the Bowden cables. The proposed design is capable of providing the required DOF in bot...

متن کامل

Initial Clinical Evaluation of the Modular Prosthetic Limb

The Modular Prosthetic Limb (MPL) was examined for its feasibility and usability as an advanced, dexterous upper extremity prosthesis with surface electromyography (sEMG) control in with two individuals with below-elbow amputations. Compared to currently marketed prostheses, the MPL has a greater number of sequential and simultaneous degrees of motion, as well as wrist modularity, haptic feedba...

متن کامل

Kinematic comparison of the wrist movements that are possible with a biomechatronics wrist prosthesis and a body-powered prosthesis: a preliminary study.

PURPOSE This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist. METHOD The subject's wrist movements were calculated and compared as he completed a wrist range of motion test involving simulated flexion/extension and supin...

متن کامل

Training protocol for a powered shoulder prosthesis.

There is a scarcity of literature on rehabilitation training protocols for upper-limb prosthesis use. Seminal textbooks and articles describe protocols for training individuals to use conventional body-powered, myoelectric, or passive prosthetic devices and were written prior to the introduction of multifunction prosthetic hands and more advanced prosthetic technologies [1–3]. Furthermore, deta...

متن کامل

Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?

Most transhumeral amputees report that their prosthetic device lacks functionality, citing the control strategy as a major limitation. Indeed, they are required to control several degrees of freedom with muscle groups primarily used for elbow actuation. As a result, most of them choose to have a one-degree-of-freedom myoelectric hand for grasping objects, a myoelectric wrist for pronation/supin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 48 6  شماره 

صفحات  -

تاریخ انتشار 2011