Use of the amplatzer vascular plug II device to occlude different types of patent ductus arteriosus in pediatric patients.
نویسندگان
چکیده
INTRODUCTION Transcatheter patent ductus arteriosus (PDA) closure is difficult in small patients in part due to the diverse PDA morphology. We describe a multicenter pediatric experience using the Amplatzer Vascular Plug II device (AVP II) to occlude PDA. METHODS All patients undergoing transcatheter closure of PDA with AVP II from April 2008 until May 2012 were included. Clinical, angiographic, and echocardiographic data were collected. RESULTS One hundred and seventy-seven procedures were performed. Median age was 14 months (2-180) with median weight 9.7 kg (4.7-68). The morphological PDA classification was Type A in 66 (37.1%), Type C in 27 (15.3%), Type D in 17 (9.6%), and Type E in 67 (37.9%). The median minimum PDA diameter was 2.6 mm (1.2-7.7 mm). The implanted device sizes were: 4 mm in 17 patients (9.6%), 6 mm in 81 (45.8%), 8 mm in 56 (31.6%), 10 mm in 18 (10.2%), and 12 mm in 5 (2.8%). The implanted device was mean of 2.6 + 0.7 times the ductus narrowest diameter and mean of 1 + 0.5 times the ductus largest diameter. Complications included: one severe left pulmonary artery stenosis and one device embolization. No aortic obstruction occurred. Closure was complete in the 175 remaining patients. CONCLUSIONS The AVP II is an effective and safe device for PDA closure. It is particularly useful when dealing with nontypical PDA shapes and in small infants where it eliminated the risk of device-related aortic obstruction. The AVPII is an addition to the PDA device closure armamentarium in pediatric patients.
منابع مشابه
Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus
Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tu...
متن کاملEvaluating the Clinical Course of Patent Ductus Arteriosus after Discharge and Comparing in Therapies Techniques
Background Patent ductus arteriosus is an open channel between the aorta and pulmonary artery. The study aimed to evaluate the clinical course of patent ductus arteriosus after discharge and comparing in therapies technique. Materials and Methods This cross-sectional and inferential- descriptive study was performed in the hospitals of city of Zahedan-Iran in the period of one decade from 2005 ...
متن کاملPercutaneous embolization of a caroticoazygous fistula with the Amplatzer Vascular Plug 1.
We present the case of a five-year-old boy with a caroticoazygous fistula, which is an extremely rare congenital vascular malformation. The patient also had patent ductus arteriosus, a common cause of continuous murmur. The murmur continued despite successful coil embolization of the ductus. Repeated catheter-angiography revealed a large caroticoazygous fistula. The fistula was successfully emb...
متن کاملPercutaneous Occlusion of Patent Ductus Arteriosus with the Amplatzer® Vascular Plug II Device: Early Experience in Three Reference Centres
Background: The conventional devices available for the percutaneous occlusion of a patent ductus arteriosus (PDA) may have limitations, especially in small children and adults with a large ductus arteriosus. The Amplatzer® Vascular Plug II (AVP II) device has been used in these scenarios with promising results. This study aims to report an early experience with the AVP II device at three refere...
متن کاملTranscatheter closure of small ductus arteriosus with amplatzer vascular plug
PURPOSE The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). METHODS We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of interventional cardiology
دوره 28 2 شماره
صفحات -
تاریخ انتشار 2015