Hydrophilic Acrylic Intraocular Lens Opacification after Descemet Stripping Automated Endothelial Keratoplasty

نویسندگان

  • Amir Norouzpour
  • Siamak Zarei-Ghanavati
چکیده

PURPOSE To report hydrophilic acylic intraocular lens (IOL) opacification after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in an eye with multiple prior intraocular surgeries and iatrogenic aniridia. CASE REPORT A 34-year-old woman with history of penetrating keratoplasty (PKP) for advanced keratoconus and subsequent Urrets-Zavalia Syndrome (UZS) underwent phacoemulsification and hydrophilic acrylic IOL implantation for her cataract. In order to control post-PKP glaucoma, multiple glaucoma surgeries including two glaucoma drainage implants were performed. As the original corneal graft failed, the patient subsequently underwent re-PKP. Four years later, she underwent DSAEK for treatment of the second graft failure. Ten months after DSAEK, a double semi-circular pattern of IOL opacification was observed on the anterior surface of the IOL. The patient did not report any complaints and we decided not to exchange the IOL. CONCLUSION In an eye with UZS and iatrogenic aniridia, IOL opacification may result from direct contact between the IOL surface and exogenous air. Aniridia can be a risk factor for development of IOL opacification after DSAEK. Further studies are required to confirm this hypothesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Opacification of hydrophilic intraocular lenses after Descemet stripping automated endothelial keratoplasty

PURPOSE Opacification of hydrophilic acrylic intraocular lenses (IOLs) is an emerging complication following Descemet stripping automated endothelial keratoplasty (DSAEK). We report six cases and review the current literature. METHODS In this retrospective, noncomparative, observational case series, patients with IOL opacification after previous DSAEK surgery were identified from corneal clin...

متن کامل

Hydrophilic intraocular lens opacification after posterior lamellar keratoplasty - a material analysis with special reference to optical quality assessment

BACKGROUND Laboratory analysis and optical quality assessment of explanted hydrophilic intraocular lenses (IOLs) with clinically significant opacification after posterior lamellar keratoplasty (DMEK and DSAEK). METHODS Thirteen opacified IOLs after posterior lamellar keratoplasty, 8 after descemet stripping automated endothelial keratoplasty (DSAEK), 3 after descemet membrane endothelial kera...

متن کامل

Combined Descemet-stripping automated endothelial keratoplasty and phacoemulsification with toric intraocular lens implantation for treatment of failed penetrating keratoplasty with high regular astigmatism.

We present the case of a 57-year-old woman who had combined Descemet-stripping automated endothelial keratoplasty (DSAEK) and phacoemulsification with implantation of a toric intraocular lens (IOL). Surgery was intended to treat a cataract developing in a post-penetrating keratoplasty (PKP) eye with high astigmatism and endothelial decompensation. Six months after uneventful surgery, the cornea...

متن کامل

Air-assisted Descemet-stripping automated endothelial keratoplasty with posterior chamber iris-fixation of aphakic iris-claw intraocular lens.

We report a combination of surgical techniques during Descemet-stripping automated endoithelial keratoplasty and intraocular lens (IOL) exchange in patients with pseudophakic bullous keratopathy and angle-supported anterior chamber IOLs. During this procedure, the anterior chamber IOL is exchanged for a posterior chamber iris-claw IOL enclavated to the posterior iris; the anterior chamber is ke...

متن کامل

Management of angle-supported intraocular lens and iridectomy in Descemet-stripping endothelial keratoplasty.

PROBLEM Effective tamponade of a Descemet-stripping endothelial keratoplasty graft with a gas bubble requires that there is no route for the bubble to escape into the posterior chamber. SOLUTION Exchange the angle-supported anterior-chamber intraocular lens (IOL) for an iris-enclaved Artisan IOL and position the IOL haptics over the peripheral iridectomy to occlude it to the extent that no ga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016