An Experimental Study of the Relative Response of Plastic Scintillators to Photons and Beta Particles
نویسنده
چکیده
A scintillation counting system has been constructed with the use of BC-400 and EJ-212 series plastic scintillators along with a subminiature photomultiplier tube to investigate the effect of increasing plastic scintillator thickness on system integrated counts. Measurements have been carried out using four different gamma sources with different energies ranging from 6keV to 1.332MeV and a Ni-63 beta source of maximum energy of 66keV. A simulation was also carried out in MCNP4a to verify the number of H-3 beta particles with max energy 18.6keV that would reach the plastic scintillator in a vacuum setting as well as in an air medium. Scintillator thicknesses ranged from 10μm to 2500μm. The response of the system was determined by measuring the integrated counts as a function of scintillator thickness. The results of these measurements showed a positive linear correlation between scintillator thicknesses and integrated counts for all the gamma sources while the slopes of the correlations of each gamma source was a function of the source energy. The beta particle response showed an initial increase of counts with scintillator thickness followed by a slight decrease. The MCNP simulation confirmed an analytical calculation of the fraction of H-3 beta particles for a given air concentration that would reach the scintillator. These results in conjunction with the experimental findings will be used to assess the potential of a plastic scintillator system forming the basis of a tritium monitor for the detection of tritium in high energy gamma backgrounds for Canadian nuclear power workers.
منابع مشابه
شبیهسازی تابع پاسخ سوسوزنهای آلی به تابش گاما و نوترون با استفاده از کدهای مونت کارلوی FLUKA،MCNPX و SCINFUL
In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...
متن کاملOptical simulation and experimental measurement of gamma ray energy spectrum of plastic scintillators with different sizes
The application of large plastic scintillators is widely increasing in the different areas of industry, medicine and security due to technical and economic advantages. One of the main disadvantages of these detectors is the unknown position of Compton edge at gamma ray spectrum. In this research, GEANT4/GATE code has been used to simulate the gamma ray spectrum for different volumes of large pl...
متن کاملConceptual Design and Simulation of Alpha-Beta Detector for Surface Contamination Measurements
The radioactive contamination measurement is essential in nuclear facilities. Monitoring of low level alpha and beta contamination is possible using light detectors high efficiency. Due to the fact that many detectors canchr('39')t simultaneously discriminate alpha, beta and gamma rays; among existing methods, phoswich detectors would be appropriate option to measure different radioactive conta...
متن کاملInvestigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملCalculations of absorbed dose and energy dependent of small-scale dosimeters for photons beam therapy
In this study, the energy dependency for dosimeters of air ionization chambers, lithium fluoride, silicon and plastic scintillator has been studied using the MCNPX Monte Carlo simulation code and simulated for gamma energy in the range of radiotherapy energy. The simulation results show that the response of each of the dosimeters for gamma photon beams in the energy range of 0.2 to 20 MeV varie...
متن کامل