Cementless Stem for Femoral Neck Fractures in a Patient’s 10th Decade of Life: High Rate of Periprosthetic Fractures

نویسندگان

  • Method Kabelitz
  • Yannick Fritz
  • Patrick Grueninger
  • Christoph Meier
  • Patrick Fries
  • Michael Dietrich
چکیده

Background Subsidence of cementless femoral stems in hemiarthroplasty (HA) and increased fracture rates are ongoing concerns of orthopedic surgeons when treating fractures in very old patients. Additionally, bone cement implantation syndrome may result in perioperative cardiac or pulmonary complications, especially in older patients, leading to morbidity and mortality. This study was performed to analyze possible subsidence and intraoperative fractures in a cohort of very old patients treated with cementless stems. Methods We retrospectively analyzed a consecutive cohort of patients aged ≥90 years with femoral neck fractures treated by uncemented HA and an anterior minimally invasive approach. Immediate full-weight bearing was allowed postoperatively. Pelvic radiographs were examined for subsidence immediately postoperatively and 6 weeks later. Results We treated 109 patients (74% women; mean age, 93 years; range, 90-102 years) by HA from January 2010 to March 2016. The 30-day mortality rate was 16%, and the morbidity rate was 47%. There were 11 (12%) intraoperative fractures: 8 (Vancouver B2) had to be addressed immediately during the primary operation, while 3 (1 Vancouver B1 and 2 Vancouver AG) were treated conservatively. One periprosthetic femoral fracture (Vancouver B1) was documented during follow-up. In 17 patients, subsidence of >2.0 mm (median, 3.9 mm; range, 2.5-9.0 mm) was documented. Conclusion Early subsidence was low in this very old cohort treated with an uncemented stem and not showing a periprosthetic fracture. The risk of intraoperative periprosthetic fractures was high. The use of uncemented implants in osteoporotic bone continues to be an intervention with high risk and should only be performed by experienced surgeons. Level of Evidence Level III, Therapeutic study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mid-term outcome of a modular, cementless, proximally hydroxyapatite-coated, anatomic femoral stem.

PURPOSE To report the mid-term outcome of a modular, cementless, proximally hydroxyapatitecoated, anatomic femoral stem in total hip arthroplasty (THA). METHODS 160 consecutive patients aged 42 to 92 (mean, 70) years underwent 185 cementless THAs for primary osteoarthritis or femoral neck fractures. All procedures were performed by a single surgeon using the same modular, cementless, proximal...

متن کامل

Proximally coated cementless bipolar hemiarthroplasty in Dorr type C bone.

The current study was conducted to examine the clinical and radiographic outcomes of cementless bipolar arthroplasty in patients who had type C bone at the time of the procedure. A total of 87 patients (105 hips) who had type C femora and had undergone cementless bipolar hemiarthroplasty with a proximally coated cementless prosthesis for the treatment of displaced femoral neck fractures at a si...

متن کامل

Treatment of periprosthetic femoral fractures after femoral revision using a long stem

BACKGROUND Periprosthetic femoral fractures are becoming increasingly common and are a major complication of total hip arthroplasty and hemiarthroplasty. The treatment of periprosthetic femoral fracture after femoral revision using a long stem is more complex and challenging. The purpose of this study was to identify the clinical and radiographical features of periprosthetic femoral fractures a...

متن کامل

Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement.

Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with pr...

متن کامل

Rare non-traumatic periprosthetic femoral fracture with features of an atypical femoral fracture: a case report

INTRODUCTION Atypical femoral fractures have emerged as one of the potential complications of bisphosphonates during the past decade. The American Society for Bone and Mineral Research published a Task Force report on atypical femoral fractures in 2010 and a second report in 2014. Although the current definition of atypical femoral fractures in these reports excludes periprosthetic fractures, e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2018