Ex vivo validation of 45 MHz intravascular ultrasound backscatter tissue characterization.
نویسندگان
چکیده
AIMS The objectives of the present study are to describe the algorithm for VH(®) IVUS using the 45-MHz rotational IVUS catheter and the associated ex vivo validation in comparison to the gold standard histology. METHODS AND RESULTS The first phase of the present study was to construct the 45 MHz VH IVUS algorithm by using a total of 55 human coronary artery specimens [111 independent coronary lesions and 510 homogenous regions of interest (ROIs)], obtained at autopsy. Regions were selected from histology and matched with their corresponding IVUS data to build the plaque classification system using spectral analysis and statistical random forests. In the second phase, the ex vivo validation of the VH IVUS algorithm assessed a total of 1060 ROIs (120 lesions from 60 coronary arteries) in comparison with histology. In an independent manner, two interventional cardiologists also classified a randomly selected subset of the ROIs for assessment of inter- and intra-observer reproducibility of VH IVUS image interpretation.When including all ROIs, the predictive accuracies were 90.8% for fibrous tissue, 85.8% for fibro fatty tissue, 88.3% for necrotic core, and 88.0% for dense calcium. The exclusion of ROIs in the acoustically attenuated areas improved the predictive accuracies, ranging from 91.9 to 96.8%. The independent analysis of randomly selected 253 ROIs showed substantial agreement for inter-observer (k = 0.66) and intra-observer (k = 0.88) reproducibility. CONCLUSION Tissue classification by 45 MHz VH IVUS technology, when not influenced by calcium-induced acoustic attenuation, provided combined tissue accuracy >88% to identify tissue types compared with the gold standard histologic assessment, with high inter- and intra-observer reproducibility.
منابع مشابه
Distribution of ultrasonic radiofrequency signal amplitude detects lipids in atherosclerotic plaque of coronary arteries: an ex-vivo study
BACKGROUND Accumulation of lipids within coronary plaques is an important process in disease progression. However, gray-scale intravascular ultrasound images cannot detect plaque lipids effectively. Radiofrequency signal analysis could provide more accurate information on preclinical coronary plaques. METHODS We analyzed 29 zones of mild atheroma in human coronary arteries acquired at autopsy...
متن کاملInvestigation of acoustic properties of silica coated gold nanoparticle as contrast agent for Ultrasonography
Interoduction: Ultrasound images have often low contrast due to small differences in acoustic impedance between different tissues. Air or gas microbubbles that surrounded by membrane are most of the contrast agents in ultrasound imaging. Problems such as instability in sound pressure and inability in penetrating from the blood vessel into body tissues limited the use of microbubbles into the in...
متن کاملCoronary plaque classification with intravascular ultrasound radiofrequency data analysis.
BACKGROUND Atherosclerotic plaque stability is related to histological composition. However, current diagnostic tools do not allow adequate in vivo identification and characterization of plaques. Spectral analysis of backscattered intravascular ultrasound (IVUS) data has potential for real-time in vivo plaque classification. METHODS AND RESULTS Eighty-eight plaques from 51 left anterior desce...
متن کاملDevelopment of a dual-modal tissue diagnostic system combining time-resolved fluorescence spectroscopy and ultrasonic backscatter microscopy.
We report a tissue diagnostic system which combines two complementary techniques of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonic backscatter microscopy (UBM). TR-LIFS evaluates the biochemical composition of tissue, while UBM provides tissue microanatomy and enables localization of the region of diagnostic interest. The TR-LIFS component consists of an optical ...
متن کاملDiagnostic accuracy of optical coherence tomography and integrated backscatter intravascular ultrasound images for tissue characterization of human coronary plaques.
OBJECTIVES The purpose of the present study was to validate the diagnostic accuracy of optical coherence tomography (OCT), integrated backscatter intravascular ultrasound (IB-IVUS), and conventional intravascular ultrasound (C-IVUS) for tissue characterization of coronary plaques and to evaluate the advantages and limitations of each of these modalities. BACKGROUND The diagnostic accuracy of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 16 10 شماره
صفحات -
تاریخ انتشار 2015