MediGuide-assisted atrial flutter ablation in a patient with a HeartMate II left ventricular assist device

نویسندگان

  • Hien Kiem Nguyen Thanh
  • Jason Andrade
  • Katia Dyrda
  • Bernard Thibault
  • Paul Khairy
  • Laurent Macle
چکیده

Hien Kiem Nguyen Thanh, MD, Jason Andrade, MD, Katia Dyrda, MD, MSc, PEng, Bernard Thibault, MD, FHRS, Paul Khairy, MD, Laurent Macle, MD, FHRS From the Electrophysiology Service, Montreal Heart Institute, Department of Medicine, Université de Montréal, Montreal, Quebec, Canada, and Electrophysiology Service, Vancouver General Hospital, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...

متن کامل

A Rare Cause of Left Ventricular Assist Device (LVAD) Obstruction: Left Atrial Dissection

Left atrial dissection is a rare factor that may cause left ventricular assist device obstruction. Prompt diagnosis and surgical repair are essential. This case report describes our experience and a successful surgical management in a patient after HeartMate 3 implantation and mitral valve inflow obstruction due to a left atrial dissection.

متن کامل

Initial clinical experience with the HeartMate II axial-flow left ventricular assist device.

The redesigned HeartMate II, an axial-flow left ventricular assist device, is simpler, smaller, and easier to operate than are pulsatile pumps. These design characteristics should make the HeartMate II more reliable and durable and broaden the eligible population base. We implanted the HeartMate II in 43 patients (average age, 42 yr). The indication for use was bridge-to-heart transplantation i...

متن کامل

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Survival after left ventricular assist device with and without temporary right ventricular support.

BACKGROUND Right ventricular (RV) failure after the insertion of a left ventricular assist device (LVAD) historically results in poor outcomes. Patients requiring temporary RV support after LVAD insertion are a heterogeneous group of patients consisting of those in cardiogenic shock after myocardial infarction, to those with chronic decompensated heart failure. For patients requiring biventricu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2015