Imaging and investigating the effects of incision angle of clear corneal cataract surgery with optical coherence tomography.

نویسندگان

  • Bin Rao
  • Jun Zhang
  • Mehran Taban
  • Peter McDonnell
  • Zhongping Chen
چکیده

Effects of incision angle in construction of clear corneal cataract incision are studied with optical coherence tomography (OCT). A stable incision angle range is found to be existent for single-planed, clear corneal cataract incisions. When well pressurized, incision angles within this stable range result in well-apposed incision edges that resist gapping while incision angles falling outside this range have a larger tendency for wound leakage. It is also shown that a two-planed incision can effectively expand the stable range. For incision angles outside the stable range, the farther the incision angle is away from stable range, the larger the gap between incision wound edges when well pressurized. These findings emphasize the significance of incision construction to the self-sealing property of clear corneal cataract incisions. Finally, we demonstrate that OCT could be an effective modality for imaging and monitoring corneal surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation of clear corneal incision architecture using optical coherence tomography

incision used in modern-day phacoemulusification cataract surgery. CCI allows sutureless surgery, induces little astigmatism and provides fast visual rehabilitation1,2. Over the past decade the incidence of endophthalmitis after cataract surgery has increased. There has been much debate on whether the increasing use of clear cornea incision has contributed to this3-5. A recent study speculated ...

متن کامل

Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

PURPOSE To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT). SETTING Private practice, Eugene, Oregon, USA. METHODS The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior citizens. The OCT images of the operative eye were taken on the first postop...

متن کامل

Architectural analysis of clear corneal incision techniques in cataract surgery using Fourier-domain OCT.

BACKGROUND AND OBJECTIVE To compare the architecture of single plane self-sealing clear corneal incision (SP-CCI) and shallow grooved self-sealing clear corneal incision (SG-CCI) after cataract surgery using Fourier-domain optical coherence tomography (FD-OCT). PATIENTS AND METHODS An FD-OCT system with a corneal adaptor module was used to image the corneal incisions in radial sections in 44 ...

متن کامل

Optical coherence tomography of the effects of stromal hydration on clear corneal incision architecture.

PURPOSE To evaluate the effects of stromal hydration on clear corneal incision (CCI) architecture immediately after surgery using anterior segment optical coherence tomography (AS-OCT). SETTING Department of Ophthalmology, Royal Berkshire Hospital, Reading, United Kingdom. METHODS Clear corneal incisions in adult eyes were examined using a Visante AS-OCT imaging system within 1 hour of surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 11 24  شماره 

صفحات  -

تاریخ انتشار 2003