Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry.
نویسندگان
چکیده
A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation step was carried out using two-level full factorial and Doehlert designs for the determination of the optimum conditions for lead preconcentration. The proposed procedure allowed the determination of lead with a detection limit of 2.2 microg L(-1), and a precision, calculated as relative standard deviation (RSD), of 2.4 and 6.8 for a lead concentration of 50.0 and 10.0 microg L(-1), respectively. A preconcentration factor of 45 and a sampling frequency of 27 samples per hour were obtained. The recovery achieved for lead determination in the presence of several cations demonstrated that this procedure has enough selectivity for analysis of environmental samples. The validation was carried out by analysis of certified reference material. This procedure was applied to lead determination in natural food.
منابع مشابه
Application of factorial design and Doehlert matrix for determination of trace lead in environmental samples by on-line column preconcentration FAAS using silica gel chemically modified with niobium(V) oxide.
In this study a new method for Pb determination in water using solid phase extraction coupled to a flow injection system and flame atomic absorption spectrometry was developed. The sorbent used for Pb preconcentration and extraction was silica gel chemically modified with niobium(V) oxide. Flow and chemical variables of the system were optimized through a multivariate procedure. The factors sel...
متن کاملFlotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry for the preconcentration and determination of cadmium (II) after optimization using experimental design
Arapid, highly sensitive and efficient flotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry has been proposed for the preconcentration and quantitative analysis of trace amounts of cadmium (II) in the presence of sodium diethyldithiocarbamateas complexingagent. Parameters including sample pH, concentration of the complexingagent, ...
متن کاملApplication of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination
The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 375 3 شماره
صفحات -
تاریخ انتشار 2003