An evaluation of the infection control potential of a UV clinical podiatry unit
نویسندگان
چکیده
BACKGROUND Infection control is a key issue in podiatry as it is in all forms of clinical practice. Airborne contamination may be particularly important in podiatry due to the generation of particulates during treatment. Consequently, technologies that prevent contamination in podiatry settings may have a useful role. The aims of this investigation were twofold, firstly to determine the ability of a UV cabinet to protect instruments from airborne contamination and secondly to determine its ability to remove microbes from contaminated surfaces and instruments. METHOD A UV instrument cabinet was installed in a University podiatry suite. Impact samplers and standard microbiological techniques were used to determine the nature and extent of microbial airborne contamination. Sterile filters were used to determine the ability of the UV cabinet to protect exposed surfaces. Artificially contaminated instruments were used to determine the ability of the cabinet to remove microbial contamination. RESULTS Airborne bacterial contamination was dominated by Gram positive cocci including Staphylococcus aureus. Airborne fungal levels were much lower than those observed for bacteria. The UV cabinet significantly reduced (p < 0.05) the observed levels of airborne contamination. When challenged with contaminated instruments the cabinet was able to reduce microbial levels by between 60% to 100% with more complex instruments e.g. clippers, remaining contaminated. CONCLUSIONS Bacterial airborne contamination is a potential infection risk in podiatry settings due to the presence of S. aureus. The use of a UV instrument cabinet can reduce the risk of contamination by airborne microbes. The UV cabinet tested was unable to decontaminate instruments and as such could pose an infection risk if misused.
منابع مشابه
New Legionella Control Options by UV and Violet LEDs for Hospitals and Care Facilities
Legionella infections caused by contaminated water are a widespread problem worldwide. Discharge lamps like mercury vapor lamps are widely known for the disinfection properties of their radiation, but they suffer technical disadvantages, like high voltages and toxic content, and are, therefore, not suitable for some infection control applications. New high-intensity ultraviolet (UV) an...
متن کاملComparison of levofloxacin versus clarithromycin efficacy in the eradication of Helicobacter pylori infection
Background: Helicobacter pylori (H.pylori) infection causes multiple upper gastrointestinal diseases but optimal therapeutic regimen which can eradicate infection in all the cases has not yet been defined. This study was designed to evaluate the efficacy of triple levofloxacin-based versus clarithromycin-based therapy. Methods: In this open-label randomized clinical trial study 120 patients ...
متن کاملEvaluation of the effect of SBAR-based patient safety training program on nurses’ clinical decision-making in the intensive care unit
Background and Aim: ICU is one of the vital departments in the hospital to reduce mortality and morbidity. The department where nurses face complex situations that require decision-making skills. In fact, problem solving is an important and complex issue clinical practice, and decision-making is an important indicator. The purpose of the study was to investigate the effect of SBAR-based patient...
متن کاملThe Effect of Using a Log Book on Nursing Students’ Clinical Competence in Intensive Care Unit
Introduction: Clinical education is a complex process in which various factors are involved. Clinical competence assessment in nursing profession is very important and one of important issues in clinical education is the improvement of its quality which requires continuous evaluation. Log book is considered as one of the most effective clinical evaluation methods. The present study was condu...
متن کاملEvaluation of Serum Interleukins-6, 8 and 10 Levels as Diagnostic Markers of Neonatal Infection and Possibility of Mortality
Objective(s): Bacterial infection contributes substantially to neonatal morbidity and mortality. Early diagnosis of neonatal sepsis is difficult because clinical signs are non-specific. We have evaluated serum IL-6, 8 and 10 as potential early diagnostic markers of neonatal infection and their relationship to mortality rate and poor prognosis. Materials and Methods : A total ...
متن کامل