Pulse-based internal calibration of polarimetric SAR

نویسندگان

  • Niels Skou
  • Erik Lintz Christensen
چکیده

Internal calibration greatly diminishes the dependence on calibration target deployment compared to external calibration. Therefore Electromagnetics Institute (EMI) at the Technical University of Denmark (TUD) has equipped its polarimetric SAR, EMISAR, with several calibration loops and developed a procedure calibrating the entire system except a few passive components which must be measured in the laboratory. The calibration procedure has a great potential as it takes into account the SAR point target response (FTR) unlike most other internal calibration schemes. However, it requires a highly stable system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of polarimetric SAR data subject to Faraday rotation using a Genetic algorithm

Recently, some spaceborne polarimetric synthetic aperture radars, such as TerraSAR X (Xband), RADARSAR-2 (C-band) and PALSAR (L-band), are available to measure a scattering matrix of terrain and polarimetric data analysis techniques are being developed for terrain classification, forest biomass and soil moisture estimations, etc. Thus polarimetric calibration is necessary to obtain the accurate...

متن کامل

SP-668 - 4th Int. Workshop on Science and Applications of SAR Polarimetry and Polarimetric Interferometry

Polarimetric calibration accuracy is a key factor in the quantitative use of polarimetric SAR data as well as the design of future SAR system. This paper presents an approach to determine the maximum acceptable distortion level remaining after polarimetric calibration in Polarimetric SAR Interferometry (Pol-InSAR). PolInSAR distortion model of calibration is reviewed and discussed firstly. Then...

متن کامل

Initial Polarimetric Calibration of PALSAR

This paper discusses an initial polarimetric calibration of ALOS PALSAR. ALOS was launched on January 24, 2006. PALSAR, which is one of ALOS three sensors, is the first spaceborne L−band polarimetric synthetic aperture radar. It is expected that PALSAR polarimetric data is used for many applications such as agriculture, forestry, ocean, natural disasters etc. Thus, polarimetric calibration is a...

متن کامل

Geometric, Radiometric, Polarimetric and Along-Track Interfer- ometric Calibration of the new F-SAR system of DLR in X-Band

Since November 2006, DLR operates F-SAR a new airborne SAR sensor beside its experimental airborne SAR sensor E-SAR. F-SAR is a totally new development utilizing most modern hardware. It is presently operated in X-band and has been supplemented recently being fully polarimetric. F-SAR already accomplished several flights and acquired SAR data in different operation modes, amongst others in alon...

متن کامل

Polarimetric and Interferometric SAR Calibration Verification Methods

It is necessary to calibrate SAR data in order to use the data for science applications. When both polarimetric and interferometric data are collected simultaneously, these SAR data can be used for cross-calibration and verification. The frequency of polarimetric and interferometric data does not have to be the same for this purpose. For example, the NASA/JPL AIRSAR system can acquire C-band in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017