Use of the Arndt wire-guided endobronchial blocker via nasal for one-lung ventilation in patient with anticipated restricted mouth opening for esophagectomy.
نویسندگان
چکیده
Functional separation of the lungs may be accomplished by several methods. Patient with restricted mouth opening has limited options for one-lung ventilation. We report the use of wire-guided endobronchial blockade, a new tool for achieving one-lung ventilation in a patient with restricted mouth opening requiring nasotracheal, fiberoptic intubation for esophagectomy and reconstruction with gastric tube substitution.
منابع مشابه
One-Lung Ventilation in a Patient with a Fresh Tracheostomy – A Case Report
After drainage of cervical abscesses, the tracheostomy was performed. For one-lung ventilation a wire guided endobronchial blocker (Arndt Blocker) was electively placed through the cannula of the fresh tracheostomy. The patient was submitted to one lung ventilation for 5 hours. Some episodes of hypoxemia required intermittent two lungs ventilation under 100% FiO2. The surgery lasted eight hours...
متن کاملUse of the Arndt wire-guided endobronchial blocker to facilitate one-lung ventilation for pediatric empyema during video-assisted thoracoscopy.
BACKGROUND Video-assisted thoracoscopic surgery (VATS) has emerged as an innovative and popular procedure for the management of postpneumonic empyema in children refractory to a medical response. One-lung ventilation is required during VATS. In this study, we evaluated the efficacy of intraoperative wire-guided endobronchial blockade (WEB) for achieving 1-lung ventilation during a thoracoscopic...
متن کاملAn update on bronchial blockers during lung separation techniques in adults.
Techniques for one-lung ventilation (OLV) can be accomplished in two ways: The first involves the use of a double-lumen endotracheal tube (DLT). The second involves blockade of a mainstem bronchus (bronchial blockers). Bronchial blockade technology is on the rise, and in some specific clinical situations (e.g., management of the difficult airway during OLV or selective lobar blockade) it can of...
متن کاملExtraluminal use of the Arndt pediatric endobronchial blocker in an infant: a case report.
PURPOSE Attaining lung isolation in the infant undergoing thoracic anesthesia can be challenging for the anesthesiologist. We describe a novel approach to performing lung isolation in an infant undergoing thoracotomy for lobectomy using an Arndt pediatric endobronchial blocker via an extraluminal technique. CLINICAL FEATURES Lung isolation in an infant was achieved through the use of an Arndt...
متن کاملA novel combination of the Arndt endobronchial blocker and the laryngeal mask airway ProSeal™ provides one-lung ventilation for thoracic surgery
In this study, the feasibility and performance of the combination of the Arndt endobronchial blocker and the laryngeal mask airway (LMA) ProSeal™ in airway establishment, ventilation, oxygenation and lung isolation was evaluated. Fifty-five patients undergoing general anesthesia for elective thoracic surgeries were randomly allocated to group Arndt (n=26) or group double-lumen tube (DLT; n=29)....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 28 1 شماره
صفحات -
تاریخ انتشار 2005