Analysis of Platelet-Rich Plasma Extraction

نویسندگان

  • Jane Fitzpatrick
  • Max K. Bulsara
  • Paul Robert McCrory
  • Martin D. Richardson
  • Ming Hao Zheng
چکیده

BACKGROUND Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. PURPOSE To determine the composition of PRP obtained from 4 commercial separation kits, which would allow assessment of current classification systems used in cross-study comparisons. STUDY DESIGN Controlled laboratory study. METHODS Three normal adults each donated 181 mL of whole blood, some of which served as a control and the remainder of which was processed through 4 PRP separation kits: GPS III (Biomet Biologics), Smart-Prep2 (Harvest Terumo), Magellan (Arteriocyte Medical Systems), and ACP (Device Technologies). The resultant PRP was tested for platelet count, red blood cell count, and white blood cell count, including differential in a commercial pathology laboratory. Glucose and pH measurements were obtained from a blood gas autoanalyzer machine. RESULTS Three kits taking samples from the "buffy coat layer" were found to have greater concentrations of platelets (3-6 times baseline), while 1 kit taking samples from plasma was found to have platelet concentrations of only 1.5 times baseline. The same 3 kits produced an increased concentration of white blood cells (3-6 times baseline); these consisted of neutrophils, leukocytes, and monocytes. This represents high concentrations of platelets and white blood cells. A small drop in pH was thought to relate to the citrate used in the sample preparation. Interestingly, an unexpected increase in glucose concentrations, with 3 to 6 times greater than baseline levels, was found in all samples. CONCLUSION This study reveals the variation of blood components, including platelets, red blood cells, leukocytes, pH, and glucose in PRP extractions. The high concentrations of cells are important, as the white blood cell count in PRP samples has frequently been ignored, being considered insignificant. The lack of standardization of PRP preparation for clinical use has contributed at least in part to the varying clinical efficacy in PRP use. CLINICAL RELEVANCE The variation of platelet and other blood component concentrations between commercial PRP kits may affect clinical treatment outcomes. There is a need for standardization of PRP for clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Study of Four Platelet-Rich Plasma Methods for Preparing Platelet Concentrates

Background: Platelet preparations have been used for a wide variety of clinical applications such as hemorrhage, tissue engineering and cellular therapy. Platelet concentrates can be prepared by the apheresis method or from the whole blood using the Buffy-coat or Platelet-rich plasma methods. The purpose of this study was to compare four variations of platelet-rich plasma method based on double...

متن کامل

Conversion from Platelet-Rich Plasma Platelet Production to Buffy Coat Platelet Component Production: Benefits and Limitations

Blood transfusion centers are under considerable pressure to produce platelet concentrates with high quality and safety due to the short shelf life of 3-5 days as well as possible bacterial and viral contaminations. For a variety of reasons, many Europeans have changed their methods of component production from whole blood using the North American standard platelet-rich plasma method to the buf...

متن کامل

A Novel Method for Iatrogenic Vesicovaginal Fistula Treatment: Autologous Platelet Rich Plasma Injection and Platelet Rich Fibrin Glue Interposition

Introduction: Vesicovaginal fistula remains a challenge in surgical therapy. In this study autologous platelet rich plasma and platelet rich fibrin glue were used as a minimally invasive approach for vesicovaginal fistula closure. Materials and Methods: Data including age, parity, ICIQ-UI (International Consultation on Incontinence Questionnaire-urinary incontinence), ICIQ-QOL (Internation...

متن کامل

Effects of Platelet-Rich Plasma & Platelet-Rich Fibrin with and without Stromal Cell-Derived Factor-1 on Repairing Full-Thickness Cartilage Defects in Knees of Rabbits

Background: The purpose of this study was to create biomaterial scaffolds like platelet-rich plasma (PRP) and platelet-rich fibrin (PRF) containing stromal cell-derived factor-1 (SDF1) as a chemokine to induce hyaline cartilage regeneration of rabbit knee in a full thickness defect.Methods: We created a full thickness defect in the trochlear groove of thirty-six bilateral knees of eighteen matu...

متن کامل

Maxillary alveolar bone grafting: the role of Platelet-rich plasma (PRF)

Introduction: Gold standard for alveolar cleft bone grafting is autogenous bone. Advantage of adding the growth factors to the bone is established, so adding PRF to the autogenous bone may have beneficial effects. Methods:  Platelet-rich plasma admixed with autogenous bone and as a biologic membrane over the bone grafted alveolar cleft was used. Results:  Autogenous bone in all (four cases...

متن کامل

Platelet-rich plasma as filling material in open sinus lift surgery

Background  Many biomaterials are used during the open sinus lift surgery, beneath the elevated scheniderian membrane and maxillary sinus bony floor but the search for Ideal material continues. Methods  In the maxillary posterior atrophic ridges with the bone height less than four millimeters the open sinus lift surgery performed. The autologous Platelet-rich plasma (PRF) was used as the sol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017