TMS Induced EEG Artifacts Analysis Based on the Partial Cross-Correlations
نویسنده
چکیده
Combining Transcranial magnetic stimulation (TMS) and Electroencephaloraphy (EEG) offered insights into neural interaction during cognition which allows the investigation on the causal role of specific brain areas in behavior and the interactive connection between the brain areas. The TMS pulse in the TMS-EEG combining study introduces artifacts in the EEG electrodes which may mask the underlying neural activity lasting about 5 through even hundreds milliseconds after the pulse. In this study a statistical method on the removal of TMS induced EEG artifacts is presented based on partial cross-correlations. The method yields estimates of linear correlations between components obtained by Independent Component Analysis (ICA) and TMS signal that are not affected by linear correlations with other artifacts. We used the EEG data obtained from four healthy subjects without any neurological disorder, who were receiving single pulse TMS-EEG and sham-EEG stimulus on the left Broca’s area. ICA filters trained on the reduced version of 60 channel EEG data collected during single pulse 1426 Unjoo Lee and Woo-Kyoung Yo TMS-EEG and sham-EEG recordings. It identified the reduced number of statistically independent source channels, in which the ICA components originating from the TMS-induced artifact are classified by estimating the partial cross-correlation coefficients between ICA components of single pulse TMS-EEG and sham-EEG stimulus after ICA decomposition. The results showed which ICA components are related to TMS induced EEG artifacts, suggesting the efficiency and the reliability of the method developed in this study.
منابع مشابه
A Reliable and Quantitative way of TMS-induced EEG Artifacts Removal
A noble reliable and quantitative method of TMS-induced EEG artifacts removal is suggested. The method is based on the cross-correlations of ICA components of interactively real TMS and fake TMS groups. FastICA algorithm was used for the ICA decomposition and FIR and notch filtering were preprocessed. A total of two healthy male subjects were selected in this study. ICA filters trained on the r...
متن کاملTMSEEG: A MATLAB-Based Graphical User Interface for Processing Electrophysiological Signals during Transcranial Magnetic Stimulation
Concurrent recording of electroencephalography (EEG) during transcranial magnetic stimulation (TMS) is an emerging and powerful tool for studying brain health and function. Despite a growing interest in adaptation of TMS-EEG across neuroscience disciplines, its widespread utility is limited by signal processing challenges. These challenges arise due to the nature of TMS and the sensitivity of E...
متن کاملAnalysing concurrent transcranial magnetic stimulation and electroencephalographic data: A review and introduction to the open-source TESA software
The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS-EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort...
متن کاملOff-line removal of TMS-induced artifacts on human electroencephalography by Kalman filter.
In this paper we present an off-line Kalman filter approach to remove transcranial magnetic stimulation (TMS)-induced artifacts from electroencephalographic (EEG) recordings. Two dynamic models describing EEG and TMS signals generation are identified from data and the Kalman filter is applied to the linear system arising from their combination. The keystone of the approach is the use of time-va...
متن کاملImproving the quality of combined EEG-TMS neural recordings: Introducing the coil spacer
BACKGROUND In the last decade, interest in combined transcranial magnetic stimulation (TMS) and electroencephalography (EEG) approaches has grown substantially. Aside from the obvious artifacts induced by the magnetic pulses themselves, separate and more sinister signal disturbances arise as a result of contact between the TMS coil and EEG electrodes. NEW METHOD Here we profile the characteri...
متن کامل