The Impact of Obstructive Sleep Apnoea and Nasal Continuous Positive Airway Pressure on Circulating Ischaemia-Modified Albumin Concentrations

نویسندگان

  • Firat Uygur
  • Hakan Tanriverdi
  • Murat Can
  • Tacettin Ornek
  • Fatma Erboy
  • Bulent Altinsoy
  • Figen Atalay
  • Murat Damar
  • Furuzan Kokturk
  • Meltem Tor
چکیده

The aim of the present study was to evaluate the impact of obstructive sleep apnoea syndrome (OSAS) and the effects of nasal continuous positive airway pressure (CPAP) on circulating ischaemia-modified albumin (IMA) concentrations. The study included 97 newly diagnosed OSAS patients and 30 nonapnoeic controls. Blood samples were obtained in the morning after polysomnography. After 3 months of CPAP treatment, 31 patients with moderate-severe OSAS were reassessed for serum IMA concentrations. Significantly higher serum IMA concentrations were measured in the OSAS group than in the control group [0.518 ± 0.091 absorbance units (ABSU), 0.415 ± 0.068 ABSU, P < 0.001]. Serum IMA concentrations correlated significantly with the apnoea-hypopnoea index, mean SaO2, desaturation index, and C-reactive protein concentrations. Multiple logistic regression analyses showed that OSAS increased the serum IMA concentration independent of age, sex, body mass index, smoking habit, and cardiovascular disease. After 3 months of treatment with CPAP, OSAS patients had significantly lower serum IMA concentrations (0.555 ± 0.062 ABSU to 0.431 ± 0.063 ABSU, P < 0.001). The results showed that OSAS is associated with elevated concentrations of IMA, which can be reversed by effective CPAP treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous sleep study and nasoendoscopic investigation in a patient with obstructive sleep apnoea syndrome refractory to continuous positive airway pressure: a case report

INTRODUCTION The standard treatment for obstructive sleep apnoea syndrome is nasal continuous positive airway pressure. In most cases the obstruction is located at the oropharyngeal level, and nasal continuous positive airway pressure is usually effective. In cases of non-response to nasal continuous positive airway pressure other treatments like mandibular advancement devices or upper airway s...

متن کامل

The cost-effectiveness of nCPAP treatment in patients with moderate-to-severe obstructive sleep apnoea.

The demand for diagnostic and therapeutic services for obstructive sleep apnoea syndrome (OSAS) showed marked growth during the 1990s. This paper analyses the long-term cost-effectiveness of nasal continuous positive airway pressure (nCPAP) treatment in comparison to conventional null treatment. A Markov model was used to represent the natural history of OSAS based upon published evidence. Util...

متن کامل

Circulating levels of vascular endothelial markers in obstructive sleep apnoea syndrome. Effects of nasal continuous positive airway pressure

INTRODUCTION Obstructive sleep apnoea syndrome (OSAS) is an important risk factor in cardiovascular disorders. Although the exact mechanism remains to be elucidated, the endothelial dysfunction process seems to be implicated. MATERIAL AND METHODS In order to test this hypothesis, blood circulating levels of endothelial markers were measured at baseline and 1 year after treatment with continuo...

متن کامل

Severe obstructive sleep apnoea treated with long term nasal continuous positive airway pressure.

Seven patients with the severe obstructive sleep apnoea syndrome were treated with nasal continuous positive airway pressure for from three to 22 months. This treatment reversed all symptoms due to the syndrome in every patient and continued to be used in five patients. One patient stopped treatment after eight months and subsequently remained incapacitated and another underwent tracheostomy at...

متن کامل

Cerebrospinal fluid leak associated with nasal continuous positive airway pressure treatment for obstructive sleep apnoea.

Clear rhinorrhoea is a common symptom in patients with obstructive sleep apnoea (OSA), which may worsen with nasal continuous positive airway pressure treatment (nCPAP). However, rhinorrhoea can also be the presenting symptom of cerebrospinal fluid (CSF) leak, which is due to a communication between the subarachnoid space and the nasal cavity or sinuses. We report another case of a patient with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016