The impact of obesity on follow-up after an abnormal screening mammogram.

نویسندگان

  • Ellen A Schur
  • Joann E Elmore
  • Tracy Onega
  • Karen J Wernli
  • Edward A Sickles
  • Sebastien Haneuse
چکیده

BACKGROUND Effective breast cancer screening and early detection are crucial for obese women, who experience a higher incidence of the disease and present at later stages. METHODS We examined the association between body mass index (BMI) and timeliness of follow-up after 241,222 abnormal screening mammograms carried out on 201,470 women in the Breast Cancer Surveillance Consortium. Each mammogram had one of three recommendations for follow-up: short-interval follow-up, immediate additional diagnostic imaging, and biopsy/surgical consultation. We used logistic regression to estimate the adjusted effect of BMI on any recorded follow-up within 270 days of the recommendation; linear regression was used to model the mean follow-up time among those with recorded follow-up. RESULTS As compared with normal-weight women, higher BMI was associated with slightly increased odds of follow-up among women who received a recommendation for short-interval follow-up (ORs: 1.03-1.10; P = 0.04) or immediate additional imaging (ORs: 1.03-1.09; P = 0.01). No association was found for biopsy/surgical consultation recommendations (P = 0.90). Among those with recorded follow-up, higher BMI was associated with longer mean time to follow-up for both short-interval (3-10 days; P < 0.001) and additional imaging recommendations (2-3 days; P < 0.001) but not biopsy/surgical consultation (P = 0.06). Regardless of statistical significance, actual differences in days to follow-up across BMI groups were small and unlikely to be clinically significant. CONCLUSIONS Once obese women access screening mammography, their follow-up after abnormal results is similar to that of normal-weight women. IMPACT Efforts to improve early detection of breast cancer in obese women should focus elsewhere, such as improving participation in screening mammography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time to follow‐up of an abnormal mammogram in women with diabetes: a population‐based study

Women with diabetes have a higher breast cancer incidence and mortality. They are also significantly less likely to undergo screening mammography and present with more advanced stage than women without diabetes. The purpose of this study was to examine if women with diabetes are more likely to have delays in follow-up of abnormal mammograms, compared to women without diabetes. Using population-...

متن کامل

What factors are associated with diagnostic follow-up after abnormal mammograms? Findings from a U.S. National Survey.

The purpose of this study was to identify factors associated with diagnostic follow-up after an abnormal mammogram in a national sample of women in the U.S. The sample was selected from the year 2000 National Health Interview Survey and included 1901 women aged 30 and above who reported ever having an abnormal mammogram. The outcome measure was receipt of at least some diagnostic follow-up afte...

متن کامل

[Timely care after an abnormal mammogram among low-income women in a public breast cancer screening program].

BACKGROUND Since 1990, the National Breast and Cervical Cancer Early Detection Program (BCCEDP) has funded breast cancer screening and diagnostic services for low-income, underinsured women. Case management was implemented in 2001 to address barriers to follow-up after an abnormal mammogram, and free treatment was introduced in 2004. However, the effect of these policies on timeliness of care h...

متن کامل

Sociodemographic Characteristics, Distance to the Clinic, and Breast Cancer Screening Results.

Timely detection and follow-up of abnormal cellular changes can aid in early diagnosis of breast cancer, thus leading to better treatment outcomes. However, despite substantial breast cancer screening initiatives, the proportion of female breast cancer cases diagnosed at late stages remains high. Distance to screening clinics may affect access to care, particularly for women living in impoveris...

متن کامل

Loss to Follow-up After Newborn Hearing Screening and Its Related Factors

Background: Hearing loss is one of the most common birth defects and early detection of this disorder at birth is not possible without hearing screening. The aim of this study was to determine the frequency of loss to-follow-up after neonatal hearing screening and its related factors in KhoramAbad Province - Iran. Methods: This retrospective correlational study was conducted in the time period...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2012