Red cell size as measured by the Coulter model S.
نویسنده
چکیده
The MCV (mean corpuscular volume) was examined by the Coulter model S. It was found that the MCV measured by the Coulter S was larger than the generally accepted range 82 to 92, or 76 to 96 mu(3). The range in 500 healthy individuals was 82.2 to 100.6 mu(3). It was also found that the mean MCV became larger with increasing age. No sex difference was found. The low MCV by manual methods was generally thought to be attributed to less accurate measurement of erythrocyte counts.
منابع مشابه
A reference blood as a control of parameters in Coulter S.
A method is described using the histologic fixation technique in the prep aration of a reference cell suspension for the quality control program in Coulter S. Some red blood cells were fixed by glutaraldehyde and then post fixed by uranyl acetate. The fixed cells were used to obtain the counts in the white blood cell bath. This method provided satisfactory between-day pre cision as compared ...
متن کاملThe red cell osmometer. A useful inaccuracy in measurement of mean corpuscular volume in hyperosmolar states.
The Coulter S Counter gives a value for mean corpuscular volume which does not necessarily reflect red cell size in vivo. This phenomenon may be used in early diagnosis and hence prevention of the 'hyperosmolar syndrome'.
متن کاملThe interrelationships and stability of Coulter S-determined blood indices.
The blood of 104 medical inpatients was examined at various intervals during storage for 72 hours using a Coulter S counter. Over this period remarkable stability of the white cell count, red cell count, haemoglobin, and mean cell haemoglobin was demonstrated. This permits a useful interpretation of indices obtained in routine postal samples sent to the laboratory by general practitioners for s...
متن کاملDesign and characterization of biodegradable polymer-clay nanocomposites prepared by solution mixing technique
This paper discusses about preparation of biodegradable polymer /clay nanocomposites based on organically modified montmorillonite clay; i.e. cloisite 10A and biodegradable polymer chitosan by solution mixing technique and their characterization. The nanocomposites were successfully prepared and their structures were characterized by powder x-ray diffraction (XRD), particle size analyzer (Beckm...
متن کاملDesign and characterization of biodegradable polymer-clay nanocomposites prepared by solution mixing technique
This paper discusses about preparation of biodegradable polymer /clay nanocomposites based on organically modified montmorillonite clay; i.e. cloisite 10A and biodegradable polymer chitosan by solution mixing technique and their characterization. The nanocomposites were successfully prepared and their structures were characterized by powder x-ray diffraction (XRD), particle size analyzer (Beckm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 25 7 شماره
صفحات -
تاریخ انتشار 1972