Role of Ion Sources for Spacer Charging in SF6 Gas Insulated HVDC Systems
نویسندگان
چکیده
Stationary DC electric fields are determined by the resistivity distribution of the insulation materials. In the presence of interfaces between different insulation materials, charge accumulation at these boundary layers may have a significant influence on the electric field distribution and with it on the breakdown strength of the arrangement. In many previous works, surface charging of model spacers was investigated. However, the ion flow problem to properly account for the electric conduction in the gas has not yet been solved. The role of different ion sources and the behavior of the resulting ion currents in the gas phase on the charge accumulation process have to be investigated in more detail. In this paper, the transient charge accumulation process on a PTFE spacer surface with a focus on charges originating from the gas phase is investigated experimentally and by simulations. These charges are produced by natural radiation. The transition of the ohmic conduction regime in the gas to a saturated ion current with increasing voltage is analyzed. Furthermore, the importance of additional charge sources like partial discharges and field emission from the electrodes is highlighted. The experimental results indicate that additional charges are generated already at voltage levels significantly below the measured PD inception voltage. These charges originate from micro discharges on the electrodes and have to be taken into account when designing HVDC GIS applications. Index Terms SF6, gas insulation, HVDC insulation, charge accumulation, surface charge, ion source, charge carrier
منابع مشابه
Influence of the Gas Volume Size on Spacer Charging in Sf6 under Dc Stress
As Gas Insulated DC transmission systems unite the advantages of space saving installation and large transmission capacity this technology is increasingly discussed and investigated today. The main problem in operation with respect to insulation seems to be identified today, which is charge accumulation on the surface of the spacer. These trapped charges can cause a reduction of dielectric stre...
متن کاملThe SF6 Decomposition Mechanism: Background and Significance
Gas Insulated Switchgear (GIS) has been widely used in substations. The insulating medium used in GIS is sulfur hexafluoride (SF6) gas. However, the internal insulation defect existed in GIS would inevitably lead to partial discharge (PD), and cause the composition of SF6 to SOF2, SO2F2 and SO2 and other characteristic component gases. The decomposition phenomenon would greatly reduce the insul...
متن کاملDielectric Strength of Different Gases in GIS
SF6 is a gas with excellent dielectric properties and is commonly used in gas-insulated equipment. However it has the high global warming potential. Thus, the development of new gases or gas mixtures for GIS, GIL is strongly desired. For dimensioning the gas insulated systems the support insulators (spacers) are of special interest. Contaminations on the insulator surface can cause field distor...
متن کاملPreparation and Application of TiO2 Nanotube Array Gas Sensor for SF6-Insulated Equipment Detection: a Review
Since Zwilling and co-workers first introduced the electrochemical anodization method to prepare TiO2 nanotubes in 1999, it has attracted a lot of researches due to its outstanding gas response and selectivity, making it widely used in gas detection field. This review presents an introduction to the sensor applications of TiO2 nanotube arrays (TNTAs) in sulfur hexafluoride (SF6)-insulated equip...
متن کاملDecomposition Characteristics of SF6 and Partial Discharge Recognition under Negative DC Conditions
Four typical types of artificial defects are designed in conducting the decomposition experiments of SF6 gas to obtain and understand the decomposition characteristics of SF6 gas-insulated medium under different types of negative DC partial discharge (DC-PD), and use the obtained decomposition characteristics of SF6 in diagnosing the type and severity of insulation fault in DC SF6 gas-insulated...
متن کامل