Antithrombin significantly influences platelet adhesion onto immobilized fibrinogen in an in-vitro system simulating low flow

نویسندگان

  • Robert Loncar
  • Uwe Kalina
  • Volker Stoldt
  • Volker Thomas
  • Rüdiger E Scharf
  • Aleksandar Vodovnik
چکیده

BACKGROUND Adhesion of platelets onto immobilized fibrinogen is of importance in initiation and development of thrombosis. According to a recent increase in evidence of a multiple biological property of antithrombin, we evaluated the influence of antithrombin on platelet adhesion onto immobilized fibrinogen using an in-vitro flow system. METHODS Platelets in anticoagulated whole blood (29 healthy blood donors) were labelled with fluorescence dye and perfused through a rectangular flow chamber (shear rates of 13 s-1 to 1500 s-1). Platelet adhesion onto fibrinogen-coated slips was assessed using a fluorescence laser-scan microscope and compared to the plasma antithrombin activity. Additionally the effect of supraphysiological AT supplementation on platelets adhesion rate was evaluated. RESULTS Within a first minute of perfusion, an inverse correlation between platelet adhesion and plasma antithrombin were observed at 13 s-1 and 50 s-1 (r = -0.48 and r = -0.7, p < 0.05, respectively). Significant differences in platelet adhesion related to low (92 +/- 3.3%) and high (117 +/- 4.1%) antithrombin activity (1786 +/- 516 U vs. 823 +/- 331 U, p < 0.05) at low flow rate (13 s-1, within first minute) have been found. An in-vitro supplementation of whole blood with antithrombin increased the antithrombin activity up to 280% and platelet adhesion rate reached about 65% related to the adhesion rate in a non-supplemented blood (1.25 +/- 0.17 vs. 1.95 +/- 0.4 p = 0.008, respectively). CONCLUSION It appears that antithrombin in a low flow system suppresses platelet adhesion onto immobilized fibrinogen independently from its antithrombin activity. A supraphysiological substitution of blood with antithrombin significantly reduces platelet adhesion rate. This inhibitory effect might be of clinical relevance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Platelet adhesion onto immobilized fibrinogen under arterial and venous in-vitro flow conditions does not significantly differ between men and women

BACKGROUND Gender-related differences in incidence of arterial thrombosis have been a focus of interest for years. The platelet integrin alphaIIbbeta3 is primarily responsible for the interaction between platelets and fibrinogen and consecutive thrombus growth. In this study, we evaluated platelet adhesion onto immobilized fibrinogen under venous and arterial flow conditions in men and women. ...

متن کامل

HPA-1 polymorphism of αIIbβ3 modulates platelet adhesion onto immobilized fibrinogen in an in-vitro flow system

BACKGROUND Platelet adhesion and subsequent thrombus formation on a subendothelial matrix at the site of vascular damage play a crucial role in the arrest of posttraumatic bleeding but also in different pathological thrombotic events, such as acute coronary syndrome and stroke. Recently published studies have clearly demonstrated that platelet integri alphaIIbbeta3 is intimately involved in the...

متن کامل

Adhesion of platelets to surface-bound fibrinogen under flow.

After platelet activation, fibrinogen mediates platelet-platelet interactions leading to platelet aggregation. In addition, fibrinogen can also function as a cell adhesion molecule, providing a substratum for adhesion of platelets and endothelial cells. In this report, we studied the adhesion of platelets to surface-immobilized fibrinogen under flow in different shear rates. Heparinized whole b...

متن کامل

The effect of surface roughness on activation of the coagulation system and platelet adhesion in rotary blood pumps.

The surface roughness of left ventricular assist devices (LVADs) is important for the biocompatibility of blood pumps. However, little is known about the effect of surface roughness on the antithrombogenicity of the device. The present study investigated the effect of surface roughness on the activation of the coagulation system and platelet adhesion in an impeller-type blood pump. Three identi...

متن کامل

Platelet collagen receptor Glycoprotein VI‐dimer recognizes fibrinogen and fibrin through their D‐domains, contributing to platelet adhesion and activation during thrombus formation

Essentials Glycoprotein VI (GPVI) binds collagen, starting thrombogenesis, and fibrin, stabilizing thrombi. GPVI-dimers, not monomers, recognize immobilized fibrinogen and fibrin through their D-domains. Collagen, D-fragment and D-dimer may share a common or proximate binding site(s) on GPVI-dimer. GPVI-dimer-fibrin interaction supports spreading, activation and adhesion involving αIIbβ3. SUM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thrombosis Journal

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2006