Accuracy of point-of-care ultrasound using low frequency curvilinear transducer in the diagnosis of shoulder dislocation and confirmation of appropriate reduction

نویسندگان

  • Javad Seyedhosseini
  • Jaleh Saiidian
  • Amirpejman Hashemi Taheri
  • Elnaz Vahidi
چکیده

Background Ultrasound (US) is an effective modality in the evaluation of shoulder dislocation and reduction. In most studies, high frequency US probes have been used. Objective To determine the sensitivity and specificity of low frequency US in the diagnosis of shoulder dislocation and its proper reduction in the emergency department (ED). Methods In a prospective observational study 84 patients, suspicious of shoulder dislocation, were enrolled in our study. In ED, they all underwent low frequency (curve) probe US examination by the emergency physician at the time of admission. Standard radiographies of their shoulder joints were taken later and then reported by the attending radiologist. As soon as the shoulder dislocation was confirmed, reduction of the joint was done under procedural sedation and analgesia. US and radiography of the relocated joint were taken for the second time. The sensitivity and specificity of low frequency US were compared with radiography by the appropriate statistical analysis. Results In comparison to radiography, US had a sensitivity of 100.0%, specificity of 80.0%, positive predictive value of 98.7%, and negative predictive value of 100.0% in diagnosis of shoulder dislocation. The specificity of US in diagnosis of proper reduction of the joint, was estimated to be 98.7% with a negative predictive value of 100.0%. US took a significantly less time than radiography to be performed (p < 0.001). Conclusions Low frequency US is highly accurate in diagnosing shoulder dislocation and its proper reduction. Thus it might be a good substitute for radiography in these situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Comparison of the effect of low-power laser with therapeutic ultrasound on the treatment of rotator cuff tendonitis

Akbari A1 1. Assistant Professor, Department of Physiotherapy, Faculty of Medicine, Zahedan University of Medical Sciences Abstract Background: Shoulder pain is the third most prevalent cause of musculoskeletal disorder after low back and cervical pains. Most of the shoulder symptoms are attributed to the rotator cuff. The objective of this study was to compare the effects of low-power ...

متن کامل

Skin disease diagnosis based on tissue frequency information analysis using sonogram patterns

Abstract Background Today early detection of common cancer with modern smart calculation is the most interesting issue due to the increased chances of successful treatment. Skin cancer is a serious and dangerous complication that threatens the lives of many people and if not diagnosed in time, it will have bad consequences. It is the fifth most common cancer in the female population and...

متن کامل

The use of ultrasonography for the confirmation of pulled elbow treatment

Objective: The aim of this study was to use ultrasonography for the diagnosis and confirmation of Pulled Elbow treatment.Methods: This descriptive cross-sectional study initiated in 2014 and continued until 2015. We used simple sampling method and recruited 60 samples among patients aged 4 months to 6 years. The apparatus used in this study was an ultraso...

متن کامل

Comparison of the Diagnostic Values of Four-Point and Two-point Ultrasound Versus CT Scan in Determining Pneumothorax

Background and Objectives: Pneumothorax is a life-threatening complication and the most common cause of which is trauma. Early diagnosis and treatment of Pneumothorax are very important. The aim of this study was to compare the diagnostic values of four-point and double-point ultrasound versus CT scan in determining pneumothorax in Rasul-Akram and Hafte-Tir Hospitals during the years 2015 - 201...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017