Endograft Migration: Incidence, Causes, and Clinical Significance
نویسندگان
چکیده
Endovascular device migration is approximately 2% at 1 year using each of the Food and Drug Administration-approved devices (Medtronic AneuRx, Gore Excluder, Cook Zenith). In this report, we review the incidence, causes, and clinical importance of endograft migration over a 5-year period after endovascular aneurysm repair with the AneuRx stent graft. In a multicenter United States clinical trial of the AneuRx device, migration was identified in 8% (94/1119) of patients over a mean follow up time of 30 ± 11 months. A Kaplan-Meier analysis determined migration rates were 1.4% at 1 year, 6.6% at 2 years, and 18.8% at 3 years. The significant factors in device migration appeared to be proximal fixation length (P = .005), renal artery to stent-graft distance (P = .001), and the clinical site (P < .001). Preimplantation aortic neck length, neck diameter, degree of device oversizing, device type (stiff vs flexible), placement of proximal extender cuffs at the original procedure, and postprocedure endoleak were not significant predictors of migration. These results highlight the importance of technical precision in stent-graft deployment as critical in preventing late AneuRx stent graft migration.
منابع مشابه
Delayed migration of a thrombosed aortic endograft within a thrombosed aneurysm sac resulting in continued sac expansion and rupture
We present the case of delayed migration of a thrombosed aortic endograft within a thrombosed aneurysm sac that expanded and ruptured. Dilation of the aortic neck likely led to endograft migration and exposure of the occluded endograft and aneurysm sac to systemic pressure. Although no endoleak was identified, a key finding on ultrasound showed mobility of the sac thrombus. This may be an indic...
متن کاملManagement of ectatic, nonaneurysmal iliac arteries during endoluminal aortic aneurysm repair.
PURPOSE Most endografts for an endoluminal AAA repair cannot achieve an adequate hemostatic seal in ectatic common iliac arteries larger than 14 mm. The extension of the endograft into the external iliac artery can alleviate this problem but requires sacrifice of the internal iliac artery. We have used the larger diameter aortic extension cuff to obtain adequate endograft to arterial wall appos...
متن کاملThe association between iliac fixation and proximal stent-graft migration during EVAR follow-up: mid-term results of 154 Talent devices.
OBJECTIVE This study investigated the importance of iliac fixation to secure endograft fixation. MATERIALS AND METHODS Computed tomography (CT) scans of patients who underwent endovascular aneurysm repair with an endoprosthesis of great columnar strength (Talent stent graft) were analysed retrospectively. Patients were enrolled consecutively between June 2000 and January 2007 and prospectivel...
متن کاملAcute aortic occlusion secondary to aortic endograft migration and collapse
Endograft migration after endovascular aneurysm repair (EVAR) is known to predispose to type Ia endoleaks and aneurysm growth but rarely leads to ischemic complications. We describe the case of a patient who presented with acute limb ischemia secondary to endograft collapse and subsequent aortic occlusion. Informed consent was obtained from the patient. The patient, a 75-year-old man, underwent...
متن کاملSideways displacement of the endograft within the aneurysm sac is associated with late adverse events after endovascular aneurysm repair.
OBJECTIVE Previous studies have shown the importance of proximal and distal endograft fixation. There is little information on the middle, unsupported section of endograft within the aneurysm sac. We quantified sideways movement of the endograft within the aneurysm sac and correlated it to late adverse events. METHODS Patients who underwent endovascular abdominal aortic aneurysm (AAA) repair ...