Design and Validation of DNA Libraries for Multiplexing Proximity Ligation Assays

نویسندگان

  • Nicolas Gobet
  • Simon Ketterer
  • Matthias Meier
چکیده

Here, we present an in silico, analytical procedure for designing and testing orthogonal DNA templates for multiplexing of the proximity ligation assay (PLA). PLA is a technology for the detection of protein interactions, post-translational modifications, and protein concentrations. To enable multiplexing of the PLA, the target information of antibodies was encoded within the DNA template of a PLA, where each template comprised four single-stranded DNA molecules. Our DNA design procedure followed the principles of minimizing the free energy of DNA cross-hybridization. To validate the functionality, orthogonality, and efficiency of the constructed template libraries, we developed a high-throughput solid-phase rolling-circle amplification assay and solid-phase PLA on a microfluidic platform. Upon integration on a microfluidic chip, 640 miniaturized pull-down assays for oligonucleotides or antibodies could be performed in parallel together with steps of DNA ligation, isothermal amplification, and detection under controlled microenvironments. From a large computed PLA template library, we randomly selected 10 template sets and tested all DNA combinations for cross-reactivity in the presence and absence of antibodies. By using the microfluidic chip application, we determined rapidly the false-positive rate of the design procedure, which was less than 1%. The combined theoretical and experimental procedure is applicable for high-throughput PLA studies on a microfluidic chip.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel Strategies and Tools for Enhanced Sensitivity in Routine Biomolecule Analytics

The combination of flexible and robust immunoassay technology with the sensitivity of DNA as a signal amplification template is realized in Immuno-PCR (“IPCR”). Classical ELISA is converted to IPCR by exchange of antibodyenzyme detection conjugates with antibody-DNA conjugates. The value of ultra-sensitive analytics deriving from this for pharmaceutical R&D is threefold: (I) Deeper understandin...

متن کامل

ProteinSeq: High-Performance Proteomic Analyses by Proximity Ligation and Next Generation Sequencing

Despite intense interest, methods that provide enhanced sensitivity and specificity in parallel measurements of candidate protein biomarkers in numerous samples have been lacking. We present herein a multiplex proximity ligation assay with readout via realtime PCR or DNA sequencing (ProteinSeq). We demonstrate improved sensitivity over conventional sandwich assays for simultaneous analysis of s...

متن کامل

Self-assembly of proximity probes for flexible and modular proximity ligation assays.

Proximity ligation assay (PLA) is a recently developed strategy for protein analysis in which antibody-based detection of a target protein via a DNA ligation reaction of oligonucleotides linked to the antibodies results in the formation of an amplifiable DNA strand suitable for analysis. Here we describe a faster and more cost-effective strategy to construct the antibody-based proximity ligatio...

متن کامل

Use of proximity ligation to screen for inhibitors of interactions between vascular endothelial growth factor A and its receptors.

BACKGROUND Improved methods are required to screen drug candidates for their influences on protein interactions. There is also a compelling need for miniaturization of screening assays, with attendant reductions in reagent consumption and assay costs. METHODS We used sensitive, miniaturized proximity ligation assays (PLAs) to monitor binding of vascular endothelial growth factor A (VEGF-A) to...

متن کامل

Cross-reactivity in antibody microarrays and multiplexed sandwich assays: shedding light on the dark side of multiplexing.

Immunoassays are indispensable for research and clinical analysis, and following the emergence of the omics paradigm, multiplexing of immunoassays is more needed than ever. Cross-reactivity (CR) in multiplexed immunoassays has been unexpectedly difficult to mitigate, preventing scaling up of multiplexing, limiting assay performance, and resulting in inaccurate and even false results, and wrong ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014