Development of a New Biofidelic Leg for Use with a Pedestrian Dummy
نویسندگان
چکیده
A new mechanical leg has been designed and developed for use in impact tests simulating pedestrian accidents. The leg has been developed to be part of a new, 50th percentile male pedestrian dummy called Polar. The leg incorporates a knee that has the essential anthropomorphic features of a 50th percentile male knee and a deformable tibia. The leg has been designed to be biofidelic under lateral impact. The knee possesses a human-like geometry that includes the femoral condyles and the tibial plateau. The four principal ligaments, namely, the posterior cruciate, anterior cruciate, the lateral collateral and the medial collateral are included along with a deformable meniscus. The tibia includes a deformable section that provides compliance during lateral loading. The femur and ankle were redesigned to attach to the knee and tibia respectively, and to a standard Hybrid III foot and femur ball joint. The leg is instrumented with two 5-axis load cells at the distal femur and proximal tibia and a 4axis load cell at the base of the tibia. This paper will present the results of component impact tests performed on the knee and compare them with Post Mortem Human Subject (PMHS) data presented by Kajzer, et al [1997]. In addition, this paper will present results from static and dynamic component tests conducted on the tibia and compare them with PMHS data presented by Yamada [1970] and Nyquist [1985].
منابع مشابه
Development of a Biofidelic 'Legform' Impact Test Device
Current EuroNCAP test specifications attempt to predict pedestrian lower limb injury in a lateral impact with a rigid legform test device developed by the UK's TRL (Transportation Research Lab). Research shows that the measurements taken from this device (knee bending angle, knee shear, and upper tibia acceleration) do not necessarily correspond to accurate injury prediction. Recent research su...
متن کاملInjury Thresholds and a Measurement Technique for the Thigh and Leg of a Pedestrian Dummy
ABSTRACT The new design of a modified lower limb of the Polar-II pedestrian dummy for enhanced biofidelity requires establishment of an alternative instrumentation to load cells. The objective of this study was to determine injury thresholds for the thigh and leg of the modified dummy, and to establish an alternative measurement technique. FE pedestrian impact simulations were run using full-bo...
متن کاملBiofidelity of Test Devices and Validity of Injury Criteria for Evaluating Knee Injuries to Pedestrians
In the current test procedure proposed by the European Enhanced Vehicle-safety Committee (EEVC) /WG17 for evaluating leg injuries to pedestrians, a legform impactor with a rigid bony structure is used. The risk of damages to knee ligaments is evaluated with the shearing displacement and the bending angle at the knee joint. A recent study has focused on evaluating biofidelity of the legform. How...
متن کاملInfluence of Vehicle Shape and Stiffness on the Pedestrian Lower Extremity Injuries: Review of Current Pedestrian Lower Leg Test Procedure
This study aims at evaluating the current pedestrian lower leg test procedure with respect to the human response in a pedestrian accident. The test procedure is examined for a variety of representative cars of the European fleet. The investigation is purely based on numerical simulations carried out using the regulatory lower leg impactor, as described in the Directive 2004/90/EC, and compared ...
متن کاملKonosu 1 DEVELOPMENT OF A BIOFIDELIC PEDESTRIAN LEGFORM IMPACTOR - INTRODUCTION OF JAMA-JARI LEGFORM IMPACTOR Ver. 2002 -
The Japan Automobile Manufacturers Association, Inc., (JAMA) and the Japan Automobile Research Institute (JARI) are collaborating to develop a biofidelic pedestrian legform impactor because the current major pedestrian legform impactor, the Transport Research Laboratory (TRL) legform impactor, lacks biofidelity. JAMA and JARI have been developing a biofidelic legform impactor since 2000. This r...
متن کامل