Unexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report

نویسندگان

  • Naomi Ono
  • Junko Nakahira
  • Sayuri Matsunami
  • Toshiyuki Sawai
  • Toshiaki Minami
چکیده

BACKGROUND Pressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. We present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct the catheter placement. CASE PRESENTATION A 74-year-old male underwent mitral valve plasty for cardiac failure caused by mitral valve regurgitation. Preoperative transthoracic echocardiography showed no septal shunt. The pulmonary artery was catheterized through a sheath introducer in the right jugular vein, and the balloon was inflated after insertion of a 15-cm catheter. The catheter was advanced until a pulmonary artery waveform was detected and the pulmonary artery wedge pressure was 21 mmHg at end-expiration. The balloon was deflated and the catheter tip was pulled back 3 cm. Pulmonary artery waveforms and appropriate a and v waves were detected, and transesophageal echocardiography confirmed the location of the catheter tip in the right pulmonary artery. The first collected blood sample had an oxygen partial pressure of 358.8 mmHg, carbon dioxide partial pressure of 20.1 mmHg, and oxygen saturation of 99%, indicating pulmonary venous blood. The pulmonary artery catheter was pulled back 5 cm, but a second blood sample showed the same results. The catheter was pulled back a further 6 cm while the location of the catheter tip was monitored on X-ray fluoroscopy. Blood gas testing through the catheter tip showed oxygen saturation of 84.4 % and oxygen partial pressure of 41.6 mmHg. Surgery was performed uneventfully. Postoperative chest radiographs showed proper placement of the pulmonary artery catheter, but radiographs on postoperative day 1 showed over-insertion, although the insertion length was unchanged. The catheter was removed. The patient was discharged 2 months postoperatively. CONCLUSIONS Our case highlights the fact that the tip of the pulmonary artery catheter can easily advance into a peripheral branch of the pulmonary artery and cause pulmonary venous blood to be sampled instead of pulmonary arterial blood. A variety of monitoring techniques are needed to confirm accurate catheter placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of Catheter Induced Upper Limb Suppurative Thrombophlebitis in a Patient after Coronary Artery Bypass Graft Surgery: a Case Report

Introduction: One of the important complications of peripheral venous catheters is suppurative thrombophlebitis that would be life threatening without treatment. In this report, we introduce a patient who developed purulent thrombophlebitis due to venous catheter in the upper limb after coronary artery bypass graft surgery. Multiple abscess formation was developed on her upper limb after the th...

متن کامل

Pulmonary Embolism as a Complication after radiofrequency catheter ablation Study: A Case Report

Pulmonary thromboembolism (PTE) is a fatal condition that may rarely occur due to complications of coronary catheter insertion. In this case report, a 41-year-old male was presented 48 hours after radiofrequency catheter ablation(RFCA) for the management of Wolf-Parkinson-White syndromewith acute onset of dyspnea, hemoptysis, and chest pain. The physical examination revealed coarse crackles in ...

متن کامل

Correlation of blood volume values and pulmonary artery catheter measurements.

OBJECTIVE To correlate the values generated by direct total blood volume measurement with pulmonary artery catheter parameters and commonly used laboratory values in the management of critically ill patients. METHODS This study was carried out at the Lutheran Medical Center, Brooklyn, New York, United States of America, during the period 1998-1999. We prospectively correlated the total blood ...

متن کامل

Superior Vena Cava Syndrome due to Thrombosis: A Rare Paraneoplastic Presentation of Bronchogenic Carcinoma

Superior vena cava (SVC) syndrome is not an uncommon occurrence in patients with malignancy and it is often described as a medical emergency. In majority of the cases, SVC syndrome occurs due to mechanical obstruction of the SVC by extraluminal compression with primary intrathoracic malignancies. However, intraluminal obstruction due to thrombosis can also produce symptoms and signs of SVC synd...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016