Dynamic measurement of human capillary blood pressure.
نویسندگان
چکیده
1. Capillary blood pressure was measured in man using a dynamic servo-nulling system and direct micropuncture. This enabled assessments of the normal variations in pressure which influence fluid filtration and reabsorption. 2. Seventy-eight capillaries in 19 subjects were punctured in one of three positions around the capillary loop with the hand at the level of the sternal angle. Mean pressure around the loop fell from 37.7 +/- 3.7 mmHg (arteriolar limb, mean +/- SEM, n = 12) to 19.4 +/- 1.0 mmHg (apex, n = 25) to 14.6 +/- 0.5 mmHg (venular limb, n = 41) at skin temperatures of 18.7-33.1 degrees C. These values agree closely with Landis' original studies in 1930 [E. Landis (1930) Heart, 15, 209-228]. 3. The mean filtration/reabsorption state of any particular capillary limb was not static because of cardiac, vasomotor and respiratory fluctuations in capillary pressure. From a total of 38 capillaries in which recordings were analysed for 30 s, the fluctuations in pressure were such that 27 capillaries probably had periods of both filtration and reabsorption. 4. Computerized superimposition and coherent averaging of trains of capillary pulses enabled an accurate description of the pulse waveform to be made in three capillaries. This was remarkably similar to waveforms from the radial artery, albeit at reduced amplitude (average 3.6 +/- 3.4 mmHg, mean +/- SD overall). The time for the pulse to travel between the radial artery and the finger capillary was approximately 10 ms, which implies a propagation velocity of several metres per second.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Modeling and investigating the effect of ultrasound waves pressure on the microbubble oscillation dynamics in microvessels containing an incompressible fluid (Research Article)
Understanding the dynamics of microbubble oscillation in an elastic microvessel is important for the safe and effective applications of ultrasound contrast agents in imaging and therapy. Numerical simulations based on 2D finite element model are performed to investigate the effect of acoustic parameters such as pressure and frequency on the dynamic interaction of the fluid-blood-vessel system. ...
متن کاملA Fully Integrated Method for Dynamic Rock Type Characterization Development in One of Iranian Off-Shore Oil Reservoir
Rock selection in modeling and simulation studies is usually based on two techniques; routinely defined rock types and those defined by special core analysis (SCAL). The challenge in utilizing these two techniques is that they are frequently assumed to be the same, but in practice, static rock-types (routinely defined) are not always representative of dynamic rock-types (SCAL defined) in the re...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کامل3D study of capillary network derived from human cord blood mesenchymal stem cells and differentiated into endothelial cell with VEGFR2 protein expression
New blood forming vessels are produced by differentiation of mesodermal precursor cells to angioblasts that become endothelial cells (ECs) which in turn give rise to primitive capillary network. Human cord blood (HCB) contains large subsets of mononuclear cells (MNCs) that can be differentiated into endothelial-like cells in vitro. Human mononuclear progenitor cells were purified from fresh umb...
متن کاملComputational simulations of nanoparticle transport in a three-dimensional capillary network
Objective(s): Multifunctional nanomedicine is the new generation of medicine, which is remarkably promising and associated with the minimum toxicity of targeted therapy. Distribution and transport of nanoparticles (NPs) in the blood flow are essential to the evaluation of delivery efficacy. Materials and Methods: In the present study, we initially designed a phantom based on Murray’s mini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 74 5 شماره
صفحات -
تاریخ انتشار 1988