Unified Grey Relational Analysis on Transformer DGA Fault Diagnosis

نویسندگان

  • Wang Qizhi
  • Wang Xiaoxia
چکیده

Power transformer is one of the most important equipments in the electric system. Dissolved Gases Analysis is an important method in the diagnosis of internal fault of transformers. Because the signs and types of fault have complicated nonlinear relations, the traditional methods cannot exactly meet the requirements of engineer application. This paper proposes synthesis of relational grey incidence to analyze the comparability and the proximity of the sequence which can effectively diagnose the type of transformer faults.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Test of Power Transformer Prior to Maintenance Using DGA and Grey Relational Analysis

The insulation of power transformer i.e. oil and paper decomposition recognized by means of dissolved gas-in-oil analysis (DGA). To detect incipient faults in a transformer, standard key gas method of DGA is employed on the basis of quantity of gases released from the oil. This primary information also reflects the overall condition of a transformer. In this paper, condition assessment of power...

متن کامل

A new approach of DGA interpretation technique for transformer fault diagnosis

Dissolved Gas Analysis (DGA) is one of the most common techniques to detect the incipient faults in the oil-filled power transformers. In this paper, a new approach of DGA technique is proposed to overcome the conflict that takes place in the traditional interpretation techniques for transformer fault diagnosis. The new approach is based on the analysis of 386 dissolved gas samples data set tha...

متن کامل

Power Transformer Incipient Faults Diagnosis Based on Dissolved Gas Analysis

Incipient fault diagnosis of a power transformer is greatly influenced by the condition assessment of its insulation system oil and/or paper insulation. Dissolved gas-in-oil analysis (DGA) is one of the most powerfull techniques for the detection of incipient fault condition within oil-immersed transformers. The transformer data has been analyzed using key gases, Doernenburg, Roger, IEC and Duv...

متن کامل

A Heuristic Approach to the Diagnosis of Transformer’s Insulating Oil

The transformer plays so important equipment in power system that engineers take more measures on the insulating oil of transformer by diagnosis. The dissolved gas analysis (DGA) is an effective technique for detecting incipient faults in oil-immersed power transformers. So the paper investigates the DGA methods, while employ the ANSI/IEEE C57.104 standards and the Key Gas diagnosis rules as ba...

متن کامل

Fuzzy Logic Application in DGA Methods to Classify Fault Type in Power Transformer

Assessment of power transformer conditions has become increasingly important in recent years. As an asset that represents one of the largest investments in a utility’s system, detection of incipient faults in power transformers is crucial. Dissolved gas-in-oil analysis (DGA) is a successful technique to detect these potential faults and it provides wealth of diagnostic information. This project...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014