Measuring diffusion of lipid-like probes in artificial and natural membranes by raster image correlation spectroscopy (RICS): use of a commercial laser-scanning microscope with analog detection.
نویسندگان
چکیده
The heterogeneity in composition and interaction within the cellular membrane translates into a wide range of diffusion coefficients of its constituents. Therefore, several complementary microfluorimetric techniques such as fluorescence correlation spectroscopy (FCS), fluorescence recovery after photobleaching (FRAP) and single-particle tracking (SPT) have to be applied to explore the dynamics of membrane components. The recently introduced raster image correlation spectroscopy (RICS) offers a much wider dynamic range than each of these methods separately and allows for spatial mapping of the dynamic properties. RICS is implemented on a confocal laser-scanning microscope (CLSM), and the wide dynamic range is achieved by exploiting the inherent time information carried by the scanning laser beam in the generation of the confocal images. The original introduction of RICS used two-photon excitation and photon counting detection. However, most CLSM systems are based on one-photon excitation with analog detection. Here we report on the performance of such a commercial CLSM (Zeiss LSM 510 META) in the study of the diffusion of the fluorescent lipid analog 1,1'-dioctadecyl-3,3,3',3'-tetramethyl-indodicarbocyanine perchlorate (DiI-C(18)(5)) both in giant unilamellar vesicles and in the plasma membrane of living oligodendrocytes, i.e., the myelin-producing cells of the central nervous system. It is shown that RICS on a commercial CLSM with analog detection allows for reliable results in the study of membrane diffusion by removal of unwanted correlations introduced by the analog detection system. The results obtained compare well with those collected by FRAP and FCS.
منابع مشابه
Raster Image Correlation Spectroscopic Analysis of Intranuclear Molecular Dynamics
In contrast to conventional epi-illumination microscopy in confocal laser scanning microscopy images are acquired sequentially either in point scanning or line scanning mode. This scanning approach therefore contains spatio-temporal information, which can be used to obtain insight into molecular dynamics, e.g. diffusion coefficients of fluorescently labeled probes. Raster Image Correlation Spec...
متن کاملFluorescence correlation spectroscopy, raster image correlation spectroscopy, and number and brightness on a commercial confocal laser scanning microscope with analog detectors (Nikon C1).
Fluorescence correlation spectroscopy (FCS) was developed in 1972 by Magde, Elson and Webb. Photon counting detectors and avalanche photodiodes have become standards in FCS to the point that there is a widespread belief that these detectors are essential to perform FCS experiments, despite the fact that FCS was developed using analog detectors. Spatial and temporal intensity fluctuation correla...
متن کاملMeasuring and imaging diffusion with multiple scan speed image correlation spectroscopy.
The intracellular mobility of biomolecules is determined by transport and diffusion as well as molecular interactions and is crucial for many processes in living cells. Methods of fluorescence microscopy like confocal laser scanning microscopy (CLSM) can be used to characterize the intracellular distribution of fluorescently labeled biomolecules. Fluorescence correlation spectroscopy (FCS) is u...
متن کاملPhotothermal raster image correlation spectroscopy of gold nanoparticles in solution and on live cells
Raster image correlation spectroscopy (RICS) measures the diffusion of fluorescently labelled molecules from stacks of confocal microscopy images by analysing correlations within the image. RICS enables the observation of a greater and, thus, more representative area of a biological system as compared to other single molecule approaches. Photothermal microscopy of gold nanoparticles allows long...
متن کاملRaster image correlation spectroscopy and number and brightness analysis.
The raster image correlation spectroscopy (RICS) and number and molecular brightness (N&B) methods are used to measure molecular diffusion in complex biological environments such as the cell interior, detect the formation of molecular aggregates, establish the stoichiometry of the aggregates, spatially map the number of mobile molecules, and quantify the relative fraction of molecules participa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Langmuir : the ACS journal of surfaces and colloids
دوره 25 9 شماره
صفحات -
تاریخ انتشار 2009