Electroanatomic mapping and radiofrequency ablation of porcine left atria and atrioventricular nodes using magnetic resonance catheter tracking.
نویسندگان
چکیده
BACKGROUND The MRI-compatible electrophysiology system previously used for MR-guided left ventricular electroanatomic mapping was enhanced with improved MR tracking, an MR-compatible radiofrequency ablation system and higher-resolution imaging sequences to enable mapping, ablation, and ablation monitoring in smaller cardiac structures. MR-tracked navigation was performed to the left atrium (LA) and atrioventricular (AV) node, followed by LA electroanatomic mapping and radiofrequency ablation of the pulmonary veins (PVs) and AV node. METHODS AND RESULTS One ventricular ablation, 7 PV ablations, 3 LA mappings, and 3 AV node ablations were conducted. Three MRI-compatible devices (ablation/mapping catheter, torqueable sheath, stimulation/pacing catheter) were used, each with 4 to 5 tracking microcoils. Transseptal puncture was performed under x-ray, with all other procedural steps performed in the MRI. Preacquired MRI roadmaps served for real-time catheter navigation. Simultaneous tracking of 3 devices was performed at 13 frames per second. LA mapping and PV radiofrequency ablation were performed using tracked ablation catheters and sheaths. Ablation points were registered and verified after ablation using 3D myocardial delayed enhancement and postmortem gross tissue examination. Complete LA electroanatomic mapping was achieved in 3 of 3 pigs, Right inferior PV circumferential ablation was achieved in 3 of 7 pigs, with incomplete isolation caused by limited catheter deflection. During AV node ablation, ventricular pacing was performed, 3 devices were simultaneously tracked, and intracardiac ECGs were displayed. 3D myocardial delayed enhancement visualized node injury 2 minutes after ablation. AV node block succeeded in 2 of 3 pigs, with 1 temporary block. CONCLUSIONS LA mapping, PV radiofrequency ablation, and AV node ablation were demonstrated under MRI guidance. Intraprocedural 3D myocardial delayed enhancement assessed lesion positional accuracy and dimensions.
منابع مشابه
Catheter ablation of paroxysmal atrial fibrillation using a 3D mapping system.
BACKGROUND We treated paroxysmal recurrent atrial fibrillation (AF) with radiofrequency (RF) catheter ablation by creating long linear lesions in the atria. To achieve line continuity, a 3D electroanatomic nonfluoroscopic mapping system was used. METHODS AND RESULTS In 27 patients with recurrent AF, a catheter incorporating a passive magnetic field sensor was navigated in both atria to constr...
متن کاملElectro-Anatomic Mapping and Radio-Frequency Ablation of Porcine Left Atria and Atrio-Ventricular Nodes using Magnetic Resonance Catheter Tracking Short Title: Schmidt et al., MR-Tracked Left Atrial Mapping and RF Ablation
From *Radiology, Brigham and Women’s Hospital, Boston, Massachusetts, †Cardiology, Massachusetts General Hospital, ‡ONI Medical Systems, Inc, Wilmington, Massachusetts, **Cardiology, University of Miami, Miami, Florida , ‡GE Global Research, Niskayuna, New York, §GE Healthcare Applied Science Laboratory, Bethesda, Maryland, St. Jude Medical, Minnetonka, Minnesota, and ‡‡Department of Radiology,...
متن کاملCombined epicardial and endocardial electroanatomic mapping in a porcine model of healed myocardial infarction.
BACKGROUND Substrate mapping of post-myocardial infarction ventricular tachycardia involves electroanatomic delineation of scarred tissue on the basis of electrogram characteristics during sinus rhythm. A percutaneous transthoracic technique was recently described that allows catheter mapping of the epicardial surface of the heart. This study sought to determine whether the epicardial extent of...
متن کاملFeasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo
BACKGROUND Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. METHODS MR t...
متن کاملView-synchronized robotic image-guided therapy for atrial fibrillation ablation: experimental validation and clinical feasibility.
BACKGROUND A robotic catheter navigation system has been developed that provides a significant degree of freedom of catheter movement. This study examines the feasibility of synchronizing this robotic navigation system with electroanatomic mapping and 3-dimensional computed tomography imaging to perform view-synchronized left atrial (LA) ablation. METHODS AND RESULTS This study consisted of a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 2 6 شماره
صفحات -
تاریخ انتشار 2009