Time - Domain Testing of a / D Converters

نویسندگان

  • D. Dallet
  • Ph. Marchegay
چکیده

Abstract: Time-domain testing of A/D converter in single tone mode amounts to the identification of fundamental and harmonic tones in noise. The variable projection method reduces this problem to frequency estimation by minimising a onedimensional function. In this paper it is shown that the bias due to ignoring the harmonic distortion effect is negligible, and this approximation leads to fast frequency estimation algorithms. Three methods are examined (Newton, Gauss-Newton and Golden section search) and compared to the method which takes into account the effect of the distortion through simulations and experimental data. The convergence and implementation issues of the algorithms are also treated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Testing of Logarithmic Analog- To-digital Converters

Abstract This paper describes test procedures to characterize the behavior of logarithmic analog-to-digital converters. Logarithmic A/D converters are usually characterized in terms of signal-to-noise ratio (SNR) or in deviation of the ideal characteristic in dB. There are a lack of test methods definition in the literature, as can be observed in the IEEE standard 1241 for these type of convert...

متن کامل

Application of Single-Frequency Time-Space Filtering Technique for Seismic Ground Roll and Random Noise Attenuation

Time-frequency filtering is an acceptable technique for attenuating noise in 2-D (time-space) and 3-D (time-space-space) reflection seismic data. The common approach for this purpose is transforming each seismic signal from 1-D time domain to a 2-D time-frequency domain and then denoising the signal by a designed filter and finally transforming back the filtered signal to original time domain. ...

متن کامل

Linearity Testing of A/D Converters Using Selective Code Measurement

Measurement of integral non-linearity (INL) and differential non-linearity (DNL) of an A/D converter using the histogram method incurs large test time. This test time can be a significant percentage of the total test time, especially for high resolution and low sampling-speed A/D converters. This paper describes a test methodology for measuring the INL and DNL specifications of A/D converters b...

متن کامل

Analysis of Power Electronic Converters Using the Developed State Space Averaging Method

Power electronic converters are non-linear time-dependent systems whose exact analysis without the use of computers is very difficult, and even using computer softwares requires a long time. Use of the state space averaging method, as will be mentioned, in addition to simplifying the analysis procedure which is a result of converting a time-dependent system to a time-independent one, reduces th...

متن کامل

Conduction and Dead-Time Voltage Drops Estimation of Asymmetric Cascaded H-Bridge Converters Utilizing Level-Shifted PWM Scheme

Linear AC power supplies can be replaced by their nonlinear switching counterparts due to the lower voltage drops and higher efficiency and power density of switching-mode inverters. Multilevel cascaded H-bridge (CHB) converters are the preferred inverter structure because of modular configuration, control, and protection. The output voltage quality in CHB converters depends on the number of ou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000