Blood Pressure Measurement Device A New Solar-Powered Blood Pressure Measuring Device for Low-Resource Settings

نویسندگان

  • Gianfranco Parati
  • Michael Ochan Kilama
  • Andrea Faini
  • Elisa Facelli
  • Kenneth Ochen
  • Cyprian Opira
  • Shanthi Mendis
  • Jiguang Wang
  • Neil Atkins
  • Eoin O’Brien
چکیده

Abstract—The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to predetermined criteria and to demonstrate the suitability of the device for low resource settings. A device, which fulfilled stipulated criteria in being inexpensive, semiautomated, and solar powered, was validated according to the International Protocol of the European Society of Hypertension; it was then subjected to field testing in 716 subjects from 2 centers in Uganda and 1 in Zambia. The Omron HEM-SOLAR having previously fulfilled accuracy criteria of the International Protocol for both systolic blood pressure (SBP) and diastolic blood pressure (DBP), fulfilled criteria for SBP, but not for DBP, when revalidated. In field testing, average SBPs and DBPs were 120.5 21.6/74.6 13.8 mm Hg and 122.3 21.8/71.2 14.0 mm Hg, respectively, with the auscultatory technique and the Omron HEM-SOLAR, respectively. Between-device agreement in defining SBP was 93.7%. The Omron HEM-SOLAR was favored over the mercury sphygmomanometer by both patients and investigators. In summary, considering the accuracy, robustness, relatively low cost, operational simplicity, and advantages such as solar power, the Omron HEM-SOLAR is likely to be a valuable device for improving BP measurement in low-resource settings with nonphysician health workers. (Hypertension. 2010;56:1047-1053.) ● Online Data Supplement

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recommendations for blood pressure measuring devices for office/clinic use in low resource settings.

This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/clinic use in low resource settings. Blood pressure measuring devices to be used in low resource settings should be accurate, affordable, and easily available worldwide. Given the ser...

متن کامل

A new solar-powered blood pressure measuring device for low-resource settings.

The management of high blood pressure (BP) is particularly inadequate in low-income countries, where the unavailability of a reliable, durable, and affordable BP-measurement device is a major obstacle to accurate diagnosis. Recognizing this, a World Health Organization committee was established to correct this deficiency by influencing manufacturers to produce a device according to predetermine...

متن کامل

گزارش یک مورد: ارسال فشار خون و نبض بیمار به پزشک با استفاده از سیستم Global system for Mobile Communications

 Background: Hypertension is a common chronic disease with increasing prevalence worldwide. Regular close monitoring of blood pressure is key point of hypertension management. Home monitoring of blood pressure has its own problems such as lack of early access to a physician in case of emergency. In this study we have designed a device that could send the patient’s self-measured blood pre...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010