Corona Resistant Kapton CR Takes Electrical Insulation Design and Reliability to New Levels
ثبت نشده
چکیده
In development and testing by DuPont with ABB Industrie AG Switzerland (a subsidiary of the multinational ABB group) and Siemens AG, two of the world’s foremost traction motor manufacturers, Kapton CR shows corona resistance or voltage endurance of greater than 100,000 hr at 20 kV/mm (500 V/mil) at 50 Hz. Kapton CR also provides twice the thermal conductivity (0.385 W/m·K) of standard Kapton. These substantial property improvements increase the margin of operational safety and open the door to new electrical design possibilities in traction motors, transformers, and electrical rotating machines.
منابع مشابه
Voltage and Pulse Endurance Test of New Generation wire CORONA - RTM developed
Inverters are commonly used in various motor applications. This greatly increases the pulse endurance stress of the wire due to switching transience. A new type of wire with two layers & three layers of Corona resistant material has been developed by BCwire® to overcome the aforementioned problem. This paper will give a brief introduction of the wire, detailed test procedure, and preliminary re...
متن کامل“Thermal Stabilization Effect” of Al2O3 nano-dopants improves the high-temperature dielectric performance of polyimide
Insulation performance of the dielectrics under extreme conditions always attracts widespread attention in electrical and electronic field. How to improve the high-temperature dielectric properties of insulation materials is one of the key issues in insulation system design of electrical devices. This paper studies the temperature-dependent corona resistance of polyimide (PI)/Al2O3 nanocomposit...
متن کاملThermal Properties of Double-aluminized Kapton at Low Temperatures
Double-aluminized kapton (DAK) is commonly used in multi-layer insulation blankets in cryogenic systems. NASA plans to use individual DAK sheets in lightweight deployable shields for satellites carrying instruments. A set of these shields will reflect away thermal radiation from the sun, the earth, and the instrument's warm side and allow the instrument's cold side to radiate its own heat to de...
متن کاملSome Important Compatibility Problems And Their Elimination In The Application Of Induction Motor With Variable Frequency Drive
It is very common to use Variable Frequency Drive (VFD) with Induction Motor (IM) in Industry due to its numerous advantages. The advance of power electronics technology has also facilitated mass utilization of this combination. However, the application of IM with VFD may affect the actual design, performance and reliability of IM. When small and medium size motors are improperly used with VFD’...
متن کاملSensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation
Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -