Coarctation of the Aorta by Velocity Encoded Cine Magnetic Resonance Imaging

نویسندگان

  • Johann C. Steffens
  • Michael W. Bourne
  • Hajime Sakuma
  • Margaret O'Sullivan
چکیده

Background Knowledge about the volume of collateral flow provides insight into the severity of coarctation of the aorta and may be critical in planning the operative approach. There is currently no method for the quantification of collateral flow in coarctation of the aorta. In this study, we applied velocity encoded cine magnetic resonance imaging (VENC-MR) to establish the flow pattern and volume of collateral flow in the descending thoracic aorta in normal subjects and patients with coarctation, introducing a new possibility to quantify the severity of the coarctation by determining the amount of collateral flow. Methods and Results VENC-MR was used to measure flow in the proximal and distal descending thoracic aorta in 10 normal subjects. In 23 patients with coarctation, flow was measured near the coarctation site and above the diaphragm. Patients were divided into a group with moderate to severe coarctation and a group with mild coarctation on the basis of clinical gradient between upper and lower extremities and the estimation of the gradient across the coarctation by Doppler echocardiography. The gradient across the coarctation and the degree of anatomic narrowing were also assessed by MR imaging. In normal volunteers, VENC-MR showed a 7±6% decrease in total flow, from proximal to distal aorta. The interobserver reproducibility was 3.9% to 4.9% (mean, 4.4%). In patients with moderate to severe coarctation, VENC-MR demonstrated an 83±50% increase in total flow from proximal to distal aorta, yielding a significant change compared with normal subjects (P<.01). Patients with mild coarctation showed a normal flow pattern and no significant change in total flow. There was a significant relation between the amount of flow increase in the distal aorta and the reduction in luminal diameter at the coarctation site (r=.94) as well as the clinical gradient (r=.84). Conclusions This study shows the normal flow pattern in the descending thoracic aorta and its reversal in coarctation due to collateral flow. Thus, VENC-MR can measure collateral flow in coarctation and serves as a unique method for providing this important measurement of the severity of coarctation of the aorta. (Circulation. 1994;90:937-943.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...

متن کامل

Cine magnetic resonance imaging for evaluation of anatomy and flow relations in infants and children with coarctation of the aorta.

Sixteen cine magnetic resonance imaging (MRI) studies were performed in 14 patients aged 1 week to 17 years (mean age, 46 months), who had coarctation of the aorta confirmed at angiography or surgery. Conventional echocardiographic-gated MRI was first performed in axial and rotated sagittal views and was used to identify the slice locations for cine MRI. Cine MRI was performed by gradient-recal...

متن کامل

Pressure fields by flow-sensitive, 4D, velocity-encoded CMR in patients with aortic coarctation.

This study compared pressure fields by 4-dimensional (4D), velocity-encoded cine (VEC) cardiac magnetic resonance imaging (CMR) with pressures measured by the clinical gold standard catheterization. Thirteen patients (n = 7 male, n = 6 female) with coarctation were studied. The 4D-VEC-CMR pressure fields were computed by solving the Pressure-Poisson equation. The agreement between catheterizati...

متن کامل

Speckle tracking for cardiac MRI in patients pre and post dilation and stent implantation of aortic coarctation

Background Current assessment techniques for regional contractility require cardiac magnetic resonance-tagged or strain encoded imaging sequences and their analysis is complex. A new steady-state free precession cine sequence (SSFP) based technique called feature tracking can readily be performed on standard SSFP sequences. To test the feasibility of feature tracking in patients with coarctatio...

متن کامل

Intercostal artery aneurysm postcoarctation repair diagnosed by magnetic resonance angiography.

A 69-year-old man was referred for investigation of a right upper chest mass. In 1965 he had an aortic coarctation resected with Dacron graft insertion. He remained asymptomatic for the intervening 33 years before presenting with breathlessness on exertion. A chest x-ray showed a right upper lobe mass, and computed tomography showed a descending aorta aneurysm. Cardiovascular magnetic resonance...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005